enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Thermal transmittance - Wikipedia

    en.wikipedia.org/wiki/Thermal_transmittance

    Although the concept of U-value (or U-factor) is universal, U-values can be expressed in different units. In most countries, U-value is expressed in SI units, as watts per square metre-kelvin: W/(m 2 ⋅K) In the United States, U-value is expressed as British thermal units (Btu) per hour-square feet-degrees Fahrenheit: Btu/(h⋅ft 2 ⋅°F)

  3. Heat transfer coefficient - Wikipedia

    en.wikipedia.org/wiki/Heat_transfer_coefficient

    Architects and engineers call the resulting values either the U-Value or the R-Value of a construction assembly like a wall. Each type of value (R or U) are related as the inverse of each other such that R-Value = 1/U-Value and both are more fully understood through the concept of an overall heat transfer coefficient described in lower section ...

  4. Vacuum insulated panel - Wikipedia

    en.wikipedia.org/wiki/Vacuum_insulated_panel

    Based on a typical k-value of 0.007 W/(m·K), the R-value of a typical 25-millimetre-thick (1 in) VIP would be 3.5 m 2 ·K/W (20 h·ft 2 ·°F/BTU). To provide the same R-value, 154 millimetres (6 in) of rockwool or 84 millimetres (3 in) of rigid polyurethane foam panel would be required.

  5. Kingspan Group - Wikipedia

    en.wikipedia.org/wiki/Kingspan_Group

    Kingspan Group plc is a building materials company based in Ireland, trading in over 80 countries with more than 210 factories employing over 22,000 people.The company operates with six divisions; Insulated Panels, Insulation, Light & Air, Water & Energy, and, Data & Flooring, Roof & Waterproofing.

  6. Insulated glazing - Wikipedia

    en.wikipedia.org/wiki/Insulated_glazing

    Greater space increases the insulation value up to a point, but eventually with a large enough gap, convection currents begin to flow carrying heat between the panes within the unit. Typically, most sealed units achieve maximum insulating values using a space of 16–19 mm (0.63–0.75 in) when measured at the centre of the IGU. [12]

  7. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    [1] [5] The SC, or shading coefficient, is used widely in the evaluation of heat gain through glass and windows. [1] [5] Finally, the SCL, or solar cooling load factor, accounts for the variables associated with solar heat load. These include the global coordinates of the site and the size of the structure. [1] [5]

  8. Window insulation - Wikipedia

    en.wikipedia.org/wiki/Window_insulation

    Although the concept of U-value (or U-factor) is universal, U-values can be expressed in different units. In most countries, U-value is expressed in SI units, as watts per square metre-kelvin: W/(m 2 ⋅K) In the United States, U-value is expressed as British thermal units (Btu) per hour-square feet-degrees Fahrenheit: Btu/(h⋅ft 2 ⋅°F)

  9. Curtain wall (architecture) - Wikipedia

    en.wikipedia.org/wiki/Curtain_wall_(architecture)

    While these curtain wall systems are more energy-efficient than older, single-glazed versions, they are still significantly less efficient than opaque (solid) wall construction. [13] For example, nearly all curtain wall systems, thermally-broken or otherwise, have a U-value of 0.2 or higher, which is equivalent to an R-value of 5 or lower. [14]