However, in the lighting industry it is often associated with the lighting power allowance (LPA) permitted by the building energy code in question. The Oregon Department of Energy defines lighting power density as "The maximum allowable lighting density permitted by the code. It is expressed in watts per square foot for a given occupancy/space ...
Several measures of light are commonly known as intensity: Radiant intensity, a radiometric quantity measured in watts per steradian (W/sr) Luminous intensity, a photometric quantity measured in lumens per steradian (lm/sr), or candela (cd) Irradiance, a radiometric quantity, measured in watts per square meter (W/m 2)
The frequency of light used in the definition corresponds to a wavelength in a vacuum of 555 nm, which is near the peak of the eye's response to light. If the 1 candela source emitted uniformly in all directions, the total radiant flux would be about 18.40 mW , since there are 4 π steradians in a sphere.
Mathematically, for the spectral power distribution of a radiant exitance or irradiance one may write: =where M(λ) is the spectral irradiance (or exitance) of the light (SI units: W/m 2 = kg·m −1 ·s −3); Φ is the radiant flux of the source (SI unit: watt, W); A is the area over which the radiant flux is integrated (SI unit: square meter, m 2); and λ is the wavelength (SI unit: meter, m).
ANSI/ASHRAE/IES Standard 90.1: Energy Standard for Buildings Except Low-Rise Residential Buildings is an American National Standards Institute (ANSI) standard published by ASHRAE and jointly sponsored by the Illuminating Engineering Society (IES) that provides minimum requirements for energy efficient designs for buildings except for low-rise residential buildings (i.e. single-family homes ...
Luminous efficacy of radiation measures the fraction of electromagnetic power which is useful for lighting. It is obtained by dividing the luminous flux by the radiant flux. [4] Light wavelengths outside the visible spectrum reduce luminous efficacy, because they contribute to the radiant flux, while the luminous flux of such light is zero ...
Ballast-swap replacement for 3 ft T12 30 W T8: 1.0, 25: 4: 32 F32T8: Ballast-swap replacement for 4 ft T12 40 W T8: 1.0, 25: 8: 59 F96T8: Ballast-swap replacement for 8 ft T12 75 W single-pin T12: 1.5, 38: 4 "25" F40UTSL Retrofit replacement for 4 ft T12 40 W on underpowered residential-grade rapid start magnetic ballasts. These are F40CW lamps ...
Pd = the power density, E = the RMS electric field strength in volts per meter, H = the RMS magnetic field strength in amperes per meter. [6] The above equation yields units of W/m 2. In the USA the units of mW/cm 2, are more often used when making surveys. One mW/cm 2 is the same power density as 10 W/m 2.