Within each size group, the plugs and sockets are keyed with certain "lugs" protruding on the outside of the plugs. [27] Higher current plugs have more lugs to prevent them from being inserted into a lower current socket outlet, while still allowing them to be inserted into a socket outlet of the same size group rated for a higher current.
The dimensions and configurations for NEMA connectors are given in ANSI/NEMA standard WD-6. [2] Underwriters Laboratories maintains UL Standard 498, [ 46 ] which specifies construction performance (e.g. durability, electrical safety, and fire-resistance) for NEMA connectors.
IEC 60309 (formerly IEC 309 and CEE 17, also published by CENELEC as EN 60309) is a series of international standards from the International Electrotechnical Commission (IEC) for "plugs, socket-outlets and couplers for industrial purposes".
Below is a list of NEMA enclosure types; these types are further defined in NEMA 250- Enclosures for Electrical Equipment. Each type specifies characteristics of an enclosure, but not, for example, a specific enclosure size. Note that higher numbers do not include the lower-numbered tests. For example, types 3, 4 and 6 are intended for outdoor ...
A small metal, plastic or fiberglass junction box may form part of an electrical conduit or thermoplastic-sheathed cable (TPS) wiring system in a building. If designed for surface mounting, it is used mostly in ceilings, concrete or concealed behind an access panel—particularly in domestic or commercial buildings [2].
No. 7/0, the largest size, is 0.50 in. (500 thou or 12.7 mm) dia., No. 1 is 0.30 in. (300 thou), and the smallest, No. 50, is 0.001 in. (1 thou or 25.4 µm). The system as a whole approximates an exponential curve, plotting diameter against gauge-number (each size is a approximately a constant multiple of the previous size). The weight per unit ...
Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it The first attempt to adopt a geometrical system was made by Messrs Brown & Sharpe in 1855.
The width of devices that are mounted on a 35 mm "top hat" DIN rail generally use "modules" as a width unit, one module being 18 mm wide. For example, a small device (e.g. a circuit breaker) may have a width of 1 module (18 mm wide), while a larger device may have a width of 4 modules (4 × 18 mm = 72 mm).