A plenum space is a part of a building that can facilitate air circulation for heating and air conditioning systems, by providing pathways for either heated/conditioned or return airflows, usually at greater than atmospheric pressure.
Plenum cable / ˈ p l ɛ n əm / is electrical cable that is laid in the plenum spaces of buildings. In the United States, plastics used in the construction of plenum cable are regulated under the National Fire Protection Association standard NFPA 90A: Standard for the Installation of Air Conditioning and Ventilating Systems.
Plenum may refer to: Plenum chamber, a chamber intended to contain air, gas, or liquid at positive pressure; Plenism, or Horror vacui the concept that "nature abhors a vacuum" Plenum (meeting), a meeting of a deliberative assembly in which all members are present; contrast with quorum; Plenum space, enclosed spaces (in buildings) used for airflow
Often refers to the space between a dropped ceiling and the structural ceiling, or a raised floor and the hard floor. Distinct from ductwork as a plenum is part of the structure itself. Cable and piping within a plenum must be properly rated for its fire and smoke indices. See also: plenum chamber psychrometric
The solution is to provide a large-volume plenum chamber between the inlet and the cylinders. This has two benefits: it evens out the difference in path restriction between cylinders (distribution across space), secondly it provides a large-volume buffer against pressure changes (distribution over time).
UFAD systems use an underfloor supply plenum located between the structural concrete slab and a raised floor system to supply conditioned air to supply outlets (usually floor diffusers), located at or near floor level within the occupied space. Air returns from the room at ceiling level or the maximum allowable height above the occupied zone.
Clean air delivery rate (CADR) is the amount of clean air an air cleaner provides to a room or space. When determining CADR, the amount of airflow in a space is taken into account. For example, an air cleaner with a flow rate of 30 cubic metres (1,000 cu ft) per minute and an efficiency of 50% has a CADR of 15 cubic metres (500 cu ft) per minute.
Air streams are mixed to save energy and improve energy efficiency by partially recirculating conditioned air.. The most common application for an air-mixing plenum is the mixing of return air (or extract air) with fresh air to provide a supply air mixture for onward distribution to the building or area which the ventilation system is serving. [1]