Search results
Results from the WOW.Com Content Network
A UPS designed for powering DC equipment is very similar to an online UPS, except that it does not need an output inverter. Also, if the UPS's battery voltage is matched with the voltage the device needs, the device's power supply will not be needed either. Since one or more power conversion steps are eliminated, this increases efficiency and ...
A common prefixed derived unit is "kilovolt-ampere" (symbol kVA). The VA rating is limited by the maximum permissible current, and the watt rating by the power-handling capacity of the device. When a UPS powers equipment which presents a reactive load with a low power factor, neither limit may safely be exceeded. [4]
A typical electrical generator rating plate contains the following parameters: [4] power rating is specified in terms of apparent power (KVA or MVA), since the exact power factor will be determined by the external factors; [5] power factor (PF) is the nominal power factor for other ratings; usually PF = 0.8; [5]
In the power systems analysis field of electrical engineering, a per-unit system is the expression of system quantities as fractions of a defined base unit quantity. . Calculations are simplified because quantities expressed as per-unit do not change when they are referred from one side of a transformer to t
As an example, a 250 kVA motor–generator operating at 300 ampere of full load current will require 1550 ampere of in-rush current during a re-closure after 5 seconds. This example used a fixed mounted flywheel sized to result in a 1 ⁄ 2 Hz per second slew rate. The motor–generator was a vertical type two-bearing machine with oil-bath ...
For alternating-current generators, all generating units connected to a common network must be synchronized, operating at the same frequency within a small tolerance. Alternatively, disparate sources can be combined to serve a common load if some external power converter, such as a rotating machine or a direct current converter system is ...
Portable transformers that transform single-phase 240 V to this 110 V split-phase system are a common piece of construction equipment. Generator sets used for construction sites are equipped to supply it directly. However, a large farm may be given a 230–0–230 (nominal) supply.
As with a UPS, one concern is that electrochemical energy is stored or emitted in the form of direct current (DC), while electric power networks are usually operated with alternating current (AC). For this reason, additional inverters are needed to connect the battery storage power plants to the high voltage network.