The flow table test or slump-flow test is a method to determine consistency of fresh concrete. Flow table test is also used to identify transportable moisture limit of solid bulk cargoes. [ 1 ] It is used primarily for assessing concrete that is too fluid (workable) to be measured using the slump test , because the concrete will not retain its ...
Self-consolidating concrete or self-compacting concrete (SCC) [1] is a concrete mix which has a low yield stress, high deformability, good segregation resistance (prevents separation of particles in the mix), and moderate viscosity (necessary to ensure uniform suspension of solid particles during transportation, placement (without external compaction), and thereafter until the concrete sets).
The R-Value test [1] measures the response of a compacted sample of soil or aggregate to a vertically applied pressure under specific conditions. This test is used by Caltrans for pavement design, replacing the California bearing ratio test.
The void ratio of a mixture of solids and fluids (gases and liquids), or of a porous composite material such as concrete, is the ratio of the volume of the voids filled by the fluids to the volume of all the solids ().
Preconsolidation pressure is the maximum effective vertical overburden stress that a particular soil sample has sustained in the past. [1] This quantity is important in geotechnical engineering, particularly for finding the expected settlement of foundations and embankments.
Meyerhof (1951, 1963) proposed a bearing-capacity equation similar to that of Terzaghi's but included a shape factor s-q with the depth term Nq. He also included depth factors and inclination factors. [Note: Meyerhof re-evaluated N_q based on a different assumption from Terzaghi and found N_q = ( 1 + sin phi) exp (pi tan phi ) / (1 - sin phi).
There are various factors that affect soil temperature, such as water content, [84] soil color, [85] and relief (slope, orientation, and elevation), [86] and soil cover (shading and insulation), in addition to air temperature. [87] The color of the ground cover and its insulating properties have a strong influence on soil temperature. [88]
However, the fill material is still necessary to support the curing concrete and its reinforcement. There are two common methods of filling - controlled fill and rolled fill. [13] Controlled fill: Fill material is compacted in several layers by a vibrating plate or roller. Sand fills areas up to around 800 mm deep, and clay may be used to fill ...