  2. Van Deemter equation - Wikipedia

    en.wikipedia.org/wiki/Van_Deemter_equation

    The van Deemter equation is a hyperbolic function that predicts that there is an optimum velocity at which there will be the minimum variance per unit column length and, thence, a maximum efficiency. The van Deemter equation was the result of the first application of rate theory to the chromatography elution process.

  3. Two-dimensional chromatography - Wikipedia

    en.wikipedia.org/wiki/Two-dimensional_chromatography

    The mobile phase strength is varied from a weak eluent composition to a stronger one. Based on linear solvent strength theory (LSST) of gradient elution for reversed phase chromatography, the relationship between retention time, instrumental variables and solute parameters is shown below. [18] t R =t 0 +t D + t 0 /b*ln(b*(k 0-t d /t 0) + 1)

  4. High-performance liquid chromatography - Wikipedia

    en.wikipedia.org/wiki/High-performance_liquid...

    In isocratic elution, the retention order does not change if the column dimensions (length and inner diameter) change – that is, the peaks elute in the same order. In gradient elution, however, the elution order may change as the dimensions or flow rate change. if they are no scaled down or up according to the change [40]

  5. Gel permeation chromatography - Wikipedia

    en.wikipedia.org/wiki/Gel_permeation_chromatography

    If the Mark–Houwink–Sakurada constants K and α are known (see Mark–Houwink equation), a plot of log [η]M versus elution volume (or elution time) for a particular solvent, column and instrument provides a universal calibration curve which can be used for any polymer in that solvent. By determining the retention volumes (or times) of ...

  6. Size-exclusion chromatography - Wikipedia

    en.wikipedia.org/wiki/Size-exclusion_chromatography

    The elution volume (Ve) decreases roughly linear with the logarithm of the molecular hydrodynamic volume. Columns are often calibrated using 4-5 standard samples (e.g., folded proteins of known molecular weight), and a sample containing a very large molecule such as thyroglobulin to determine the void volume. (Blue dextran is not recommended ...

  7. Elution - Wikipedia

    en.wikipedia.org/wiki/Elution

    Elution then is the process of removing analytes from the adsorbent by running a solvent, called an "eluent", past the adsorbent–analyte complex. As the solvent molecules "elute", or travel down through the chromatography column, they can either pass by the adsorbent–analyte complex or displace the analyte by binding to the adsorbent in its ...

  8. Comprehensive two-dimensional gas chromatography - Wikipedia

    en.wikipedia.org/wiki/Comprehensive_two...

    For example, GC Image was the first software developed for two dimensional gas chromatography. Some software [15] packages are used in addition to the normal GC (or GC-MS) packages while others are built as a complete platform, [16] [17] controlling all aspects of the analysis. The new and different way of presenting and evaluating data offers ...

  9. Column chromatography - Wikipedia

    en.wikipedia.org/wiki/Column_chromatography

    The mobile phase or eluent is a solvent or a mixture of solvents used to move the compounds through the column. It is chosen so that the retention factor value of the compound of interest is roughly around 0.2 - 0.3 in order to minimize the time and the amount of eluent to run the chromatography. The eluent has also been chosen so that the ...