Search results
Results from the WOW.Com Content Network
The decibel originates from methods used to quantify signal loss in telegraph and telephone circuits. Until the mid-1920s, the unit for loss was miles of standard cable (MSC). 1 MSC corresponded to the loss of power over one mile (approximately 1.6 km) of standard telephone cable at a frequency of 5000 radians per second (795.8 Hz), and matched closely the smallest attenuation detectable to a ...
A graph of the A-, B-, C- and D-weightings across the frequency range 10 Hz – 20 kHz Video illustrating A-weighting by analyzing a sine sweep (contains audio). A-weighting is a form of frequency weighting and the most commonly used of a family of curves defined in the International standard IEC 61672:2003 and various national standards relating to the measurement of sound pressure level. [1]
B-weighted sound pressure level is written either as dB B or L B, and C-weighted sound pressure level is written either as dB C or L C. Unweighted sound pressure level is called "linear sound pressure level" and is often written as dB L or just L. Some sound measuring instruments use the letter "Z" as an indication of linear SPL. [13]
Sound exposure level (SEL) is a logarithmic measure of the sound exposure of a sound relative to a reference value. Sound exposure level, denoted L E and measured in dB , is defined by [ 1 ]
Sound has three basic components, the wavelength, frequency, and speed. In sound measurement, we measure the loudness of the sound in decibels (dB). Decibels are logarithmic with 0 dB as the reference. [1] There are also a range of frequencies that sounds can have. Frequency is the number of times a sine wave repeats itself in a second. [2]
The Sound Reduction Index is expressed in decibels (dB). It is the weighted sound reduction index for a partition or single component only. This is a laboratory-only measurement, which uses knowledge of the relative sizes of the rooms in the test suite, and the reverberation time in the receiving room, and the known level of noise which can pass between the rooms in the suite by other routes ...
Dynamic range is a measure of how small you can measure a signal relative to the maximum input signal the device can measure. Expressed in decibels, the dynamic range is 20 log (Vmax/Vmin). For example, a device with an input range of ±10 V and a dynamic range of 110 dB will be able to measure a signal as small as 10 μV.
The sound energy density level gives the ratio of a sound incidence as a sound energy value in comparison to the reference level of 1 pPa (= 10 −12 pascals). [2] It is a logarithmic measure of the ratio of two sound energy densities. The unit of the sound energy density level is the decibel (dB), a non-SI unit accepted for use with the SI ...