enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Automatic bleeding valve - Wikipedia

    en.wikipedia.org/wiki/Automatic_bleeding_valve

    Brass-bodied float valve. An automatic bleeding valve or air release valve (ARV) is a plumbing valve used to automatically release trapped air from a heating system. Air, or other gas, may collect within plumbing. For water delivery systems to taps and basins, particularly with good main supply pressure, this air is usually flushed through with ...

  3. Reduced pressure zone device - Wikipedia

    en.wikipedia.org/wiki/Reduced_pressure_zone_device

    Reduced pressure zone device connected to a fire hydrant. A reduced pressure zone device (RPZD, RPZ, or RPZ valve) is a type of backflow prevention device used to protect water supplies from contamination. RPZDs may also be known as reduced pressure principle (RP), reduced pressure principle backflow prevention devices, [1][2] reduced pressure ...

  4. Larner–Johnson valve - Wikipedia

    en.wikipedia.org/wiki/Larner–Johnson_valve

    A Larner–Johnson valve is a mechanism used in dams and water pumping to control the flow of water through large pipes. The valve is suited to handling high velocity flow with minimal turbulence, even when partially open, and the actuating force can be provided by the water flow it is controlling. It was manufactured in the early 20th century ...

  5. Solenoid valve - Wikipedia

    en.wikipedia.org/wiki/Solenoid_valve

    A solenoid valve is an electromechanically operated valve. Solenoid valves differ in the characteristics of the electric current they use, the strength of the magnetic field they generate, the mechanism they use to regulate the fluid, and the type and characteristics of fluid they control. The mechanism varies from linear action, plunger-type ...

  6. Flow coefficient - Wikipedia

    en.wikipedia.org/wiki/Flow_coefficient

    A simplified version of the definition is: The k v factor of a valve indicates "The water flow in m 3 /h, at a pressure drop across the valve of 1 kgf/cm 2 when the valve is completely open. The complete definition also says that the flow medium must have a density of 1000 kg/m 3 and a kinematic viscosity of 10 −6 m 2 /s , e.g. water.

  7. List of vacuum tubes - Wikipedia

    en.wikipedia.org/wiki/List_of_vacuum_tubes

    YD1336 – 1.8 kW, Air-cooled, UHF power triode. YD1342 – 30 MHz, 530 kW, Water-cooled RF power triode. YD1352S (8867, DX334) – 5 MHz, 2 kW, Water-cooled Neotron, a gridless field-effect tube where a magnetically focused electron beam is modulated by varying the voltage of a gate electrode surrounding it.

  8. List of wave power projects - Wikipedia

    en.wikipedia.org/wiki/List_of_wave_power_projects

    The device consists of two floats connected by a hinge and uses the atmospheric pressure acting on its large surface to stick to the ocean. This allows it to follow the waves, using the motion of the two floats to convert both kinetic and potential energy to electricity by a mechanical power take-off system.

  9. Float chamber - Wikipedia

    en.wikipedia.org/wiki/Float_chamber

    The valve is often described as a needle valve, although this is a misnomer. A true needle valve uses a tapered needle in a tapered seat, so as to provide fine control over flow rate. The float valve uses a pointed needle against a square-edged seat, to give a positive shut-off. As the float relies on gravity, the chamber must be mounted ...