enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. National Fire Protection Association - Wikipedia

    en.wikipedia.org/wiki/National_Fire_Protection...

    The committee's initial report evolved into NFPA 13, Standard for the Installation of Sprinkler Systems, the most widely used fire sprinkler standard. [ 6 ] Around 1904, the NFPA began to expand its membership from affiliates of fire insurance companies to many other organizations and individuals, and also expanded its mission beyond ...

  3. Fire sprinkler system - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler_system

    Water flow from sprinklers, needed to control the fire, is delayed until the air is vented from the sprinklers. In regions using NFPA 13 regulations, the time it takes water to reach the hydraulically remote sprinkler from the time that sprinkler is activated is limited to a maximum of 60 seconds.

  4. Fire sprinkler - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler

    The 2002 edition of the NFPA #13 standard, section 3.6.1 defines quick response sprinklers as having a response time index (RTI) of 50 (meter-seconds) 1/2 or less. RTI is a measure of how thermally responsive the heat-responsive element of the sprinkler is, measured as the time needed to raise the temperature of the sprinkler bulb to 63% of the ...

  5. Cubicle curtain - Wikipedia

    en.wikipedia.org/wiki/Cubicle_curtain

    The maximum vertical mesh length required is eighteen inches (18") regardless of additional distance from the ceiling sprinkler head. The code for the vertical mesh requirement is found under National Fire Protection Agency code NFPA 13. The lower portion of the cubicle curtain is opaque to ensure patient privacy.

  6. Hydraulic calculation - Wikipedia

    en.wikipedia.org/wiki/Hydraulic_calculation

    The hydraulic calculation procedure is defined in the applicable reference model codes such as that published by the US-based National Fire Protection Association (NFPA), [2] or the EN 12845 standard, Fixed firefighting system – Automatic sprinkler systems – Design, installation and maintenance. [3]

  7. Fire suppression system - Wikipedia

    en.wikipedia.org/wiki/Fire_suppression_system

    This organization writes codes, regulations, and recommendations on the proper installation and maintenance of these fire suppression systems. Likewise, the NFPA also lists criteria that must be met for the requirements of certain types of fire suppression systems. [2]

  8. Fire protection engineering - Wikipedia

    en.wikipedia.org/wiki/Fire_protection_engineering

    The practice of final fire sprinkler systems design and hydraulic calculations is commonly performed by design technicians who are often educated in-house at contracting firms throughout North America, with the objective of preparing designers for certification by testing by associations such as NICET (National Institute for Certification in ...

  9. Glossary of firefighting equipment - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_firefighting...

    Also known as a closet ladder, folding ladder or "pencil ladder." Required to be carried on pumpers by NFPA 1901. Automatic sprinkler System of pipes serving fire sprinklers, for automatically directing water to a fire when the sprinkler is heated to its actuation temperature (usually 155 deg F).