Re: Fluke 87V displaying "Lead" and sounding beeper when nothing is plugged in. There is also one other thing to look at when you have a unit with this issue. After taking the unit apart have the board face you like normal. To the right and just above the (+) input terminal is a white ceramic resistor network.
Re: Fluke 87V LEAD alert. yes it is a intermittent fault when the leads are in the correct sockets for the measurement selection and i rarely take mA or A measurement through my leads in those sockets. I use a i200s for current. It has only ever happened to me when the leads are plugged into the com and v sockets and seems to starts as soon as ...
12AWG copper has a resistance of approximately 0.00521 ohms per meter. 0.75” = 19.05mm = 0.01905m. So the resistance of one probe tip is 0.00521 x 0.01905 = 0.0000992505 ohms. That’s about 100μOhm, significantly less than the 406μOhm you calculated (which would be correct for 18AWG). The 200μOhm probe resistance is an order of magnitude ...
Re: Test Leads on Multimeters, proper way to store them? If someone borrows your meter and returns it with the leads wrapped around it, replace the leads before using the meter." Would have spent about $10K in leads if I followed that advice. 20+ yrs now wrapping my leads around the meter and tossing in a tool bag.
The fluke TL175 test leads I normally use for everyday testing always seem to have 0.5 ohm resistance reading. I’ve tired cleaning the test leads and meter connection ports but it makes little difference. I have even tested a set of brand new fluke TL175 lead and the have about the same resistance. I tested them both on a Fluke 87v and 289.
Because as best I can tell, Fluke doesn’t make any 3m multimeter leads, just 1.5m. (They sell the TL221 straight leads that come with couplers to extend existing leads.) However, there is the TL1550B test lead set intended for their megohm meters.
My Fluke 87 started beeping when I tried to use it again after leaving it sitting under the house on an aircon external unit hot and vibrating. Solder joints look fine. Small amount of debris in the receptacles. Probably just enough in the groove in the bottom corner to short the halves of the terminals.
Re: FLUKE 289, shows message "warning leads connected incorrectly", I have detected. Osram SFH 325 FA-3 worked too. "The Diode DS2 is an infrared {LED} diode. Replacement with an SMD 0805 sized IR diode with 940nm wavelength seems to work just fine. In my case a Harvatek HT-170IRAJ was used.
My Hirschmann leads are rated to 60Vdc, but these are stackable banana types that I use on the bench power supplies. 0,5 mm² conductor not sure what the AWG is. That was some thin cables my test leads are 1mm² with double isolation and 2.5mm² with single layer of isolation. Logged.
Re: Multimeter test leads. « Reply #20 on: September 12, 2014, 02:20:12 am ». If you are in the USA the Pomona 5519A are available for very cheap. Silicone leads, solid build quality (same exact leads as the Fluke TL71, which owns Pomona) and available for under $15.