The following table is split into two groups based on whether it has a graphical visual interface or not. The latter requires a separate program to provide that feature, such as Qucs-S, [1] Oregano, [2] or a schematic design application that supports external simulators, such as KiCad or gEDA.
Short circuit analysis analyzes the power flow after a fault occurs in a power network. The faults may be three-phase short circuit, one-phase grounded, two-phase short circuit, two-phase grounded, one-phase break, two-phase break or complex faults. Results of such an analysis may help determine the following: Magnitude of the fault current
While there are strictly analog [2] electronics circuit simulators, popular simulators often include both analog and event-driven digital simulation [3] capabilities, and are known as mixed-mode or mixed-signal simulators if they can simulate both simultaneously. [4] An entire mixed signal analysis can be driven from one integrated schematic ...
Widely used as the basis for many GUI-based programs on many platforms. Version 2 is open source, but Versions 3 and 4 are commercially licensed. Momentum: commercial Yes Yes Partial Yes Yes equidistant MoM: For passive planar elements development, integrated into Keysight EEsof Advanced Design System. Ansys HFSS: commercial Yes Yes Yes Yes Yes
As an example, a 250 kVA motor–generator operating at 300 ampere of full load current will require 1550 ampere of in-rush current during a re-closure after 5 seconds. This example used a fixed mounted flywheel sized to result in a 1 ⁄ 2 Hz per second slew rate. The motor–generator was a vertical type two-bearing machine with oil-bath ...
The doubly fed generator rotors are typically wound with 2 to 3 times the number of turns of the stator. This means that the rotor voltages will be higher and currents respectively lower. Thus in the typical ±30% operational speed range around the synchronous speed, the rated current of the converter is accordingly lower which leads to a lower ...
The motor provides the power, turning the generator at a constant speed, and the signal to be amplified is applied to the generator's field winding. The higher the current applied to the winding, the stronger the magnetic field and thus the higher the output voltage of the generator. So the output voltage of the generator is an amplified copy ...
A ball bearing motor is an unusual electric motor that consists of two ball-bearing-type bearings, with the inner races mounted on a common conductive shaft, and the outer races connected to a high current, low voltage power supply. An alternative construction fits the outer races inside a metal tube, while the inner races are mounted on a ...