enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Intermittent fault - Wikipedia

    en.wikipedia.org/wiki/Intermittent_fault

    Intermittent faults are notoriously difficult to identify and repair ("troubleshoot") because each individual factor does not create the problem alone, so the factors can only be identified while the malfunction is actually occurring. The person capable of identifying and solving the problem is seldom the usual operator.

  3. Silicon bandgap temperature sensor - Wikipedia

    en.wikipedia.org/wiki/Silicon_bandgap...

    A circuit that forces I C1 and I C2 to have a fixed N:1 ratio, [2] gives the relationship: = ⁡ An electronic circuit, such as the Brokaw bandgap reference, that measures ΔV BE can therefore be used to calculate the temperature of the diode. The result remains valid up to about 200 °C to 250 °C, when leakage currents become large enough to ...

  4. Indoor–outdoor thermometer - Wikipedia

    en.wikipedia.org/wiki/Indoor–outdoor_thermometer

    In an indoor–outdoor thermometer based on a conventional liquid-in-glass thermometer, the stem of the outdoor thermometer is connected to the bulb by a long, flexible or semi-rigid capillary. The temperature scale is marked on the stem as usual. However, the temperature that is actually measured is the temperature at the bulb. [1]

  5. Thermistor - Wikipedia

    en.wikipedia.org/wiki/Thermistor

    An NTC is commonly used as a temperature sensor, or in series with a circuit as an inrush current limiter. With PTC thermistors, resistance increases as temperature rises; usually because of increased thermal lattice agitations, particularly those of impurities and imperfections. PTC thermistors are commonly installed in series with a circuit ...

  6. Failure of electronic components - Wikipedia

    en.wikipedia.org/wiki/Failure_of_electronic...

    A resistor removed from a high voltage tube circuit shows damage from voltaic arcing on the resistive metal oxide layer. Resistors can fail open or short, alongside their value changing under environmental conditions and outside performance limits. Examples of resistor failures include: Manufacturing defects causing intermittent problems.

  7. Temperature data logger - Wikipedia

    en.wikipedia.org/wiki/Temperature_data_logger

    These monitor the temperature of the product being shipped. Some data loggers are placed on the outside of the package or in the truck or intermodal container to monitor the air temperature. Placement of data loggers and sensors is critical: Studies have shown that temperatures inside a truck or intermodal container are strongly affected by ...

  8. Overheating (electricity) - Wikipedia

    en.wikipedia.org/wiki/Overheating_(electricity)

    Circuit-breakers can be placed at portions of a circuit in series to the path of current it will affect. If more current than expected goes through the circuit-breaker, the circuit breaker "opens" the circuit and stops all current. A fuse is a common type of circuit breaker that involves direct effect of Joule-overheating.

  9. Resistance thermometer - Wikipedia

    en.wikipedia.org/wiki/Resistance_thermometer

    UPRTs have a wide temperature range (−200 °C to 1000 °C) and are approximately accurate to ±0.001 °C over the temperature range. UPRTs are only appropriate for laboratory use. Another classification of laboratory PRTs is Standard Platinum Resistance Thermometers (Standard SPRTs). They are constructed like the UPRT, but the materials are ...