enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Microscopy with UV surface excitation - Wikipedia

    en.wikipedia.org/wiki/Microscopy_with_UV_surface...

    The microscope setup is based on an inverted microscope design. [ 2 ] [ 3 ] [ 4 ] An automated stage is used to record larger areas by mosaicing a series of single adjacent frames. The LED light is focused using a ball lens with a short focal length onto the sample surface in an oblique-angle cis-illumination scheme since standard microscopy ...

  3. Bright-field microscopy - Wikipedia

    en.wikipedia.org/wiki/Bright-field_microscopy

    The light path of a bright-field microscope is extremely simple; no additional components are required beyond the normal light-microscope setup. The light path begins at the illuminator or the light source on the base of the microscope. Often a halogen lamp is used. The light travels through the objective lens into the ocular lens, through ...

  4. Dark-field microscopy - Wikipedia

    en.wikipedia.org/wiki/Dark-field_microscopy

    Diagram illustrating the light path through a dark-field microscope. The steps are illustrated in the figure where an inverted microscope is used. Light enters the microscope for illumination of the sample. A specially sized disc, the patch stop (see figure), blocks some light from the light source, leaving an outer ring of illumination. A wide ...

  5. Ultramicroscope - Wikipedia

    en.wikipedia.org/wiki/Ultramicroscope

    An ultramicroscope is a microscope with a system that lights the object in a way that allows viewing of tiny particles via light scattering, and not light reflection or absorption. When the diameter of a particle is below or near the wavelength of visible light (around 500 nanometers ), the particle cannot be seen in a light microscope with the ...

  6. Microscopy - Wikipedia

    en.wikipedia.org/wiki/Microscopy

    A two-photon microscope is also a laser-scanning microscope, but instead of UV, blue or green laser light, a pulsed infrared laser is used for excitation. Only in the tiny focus of the laser is the intensity high enough to generate fluorescence by two-photon excitation , which means that no out-of-focus fluorescence is generated, and no pinhole ...

  7. Köhler illumination - Wikipedia

    en.wikipedia.org/wiki/Köhler_illumination

    Köhler illumination is a method of specimen illumination used for transmitted and reflected light (trans- and epi-illuminated) optical microscopy.Köhler illumination acts to generate an even illumination of the sample and ensures that an image of the illumination source (for example a halogen lamp filament) is not visible in the resulting image.

  8. Newton's rings - Wikipedia

    en.wikipedia.org/wiki/Newton's_rings

    Newton's rings observed through a microscope. The smallest increments on the superimposed scale are 100 μm. The illumination is from below, leading to a bright central region. Newton's rings interference pattern created by a plano-convex lens illuminated by 650 nm red laser light, photographed using a low-light microscope. The illumination is ...

  9. Fluorescence imaging - Wikipedia

    en.wikipedia.org/wiki/Fluorescence_imaging

    Images can be produced from a variety of methods including: microscopy, imaging probes, and spectroscopy. Fluorescence itself, is a form of luminescence that results from matter emitting light of a certain wavelength after absorbing electromagnetic radiation. Molecules that re-emit light upon absorption of light are called fluorophores. [1] [2]