enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Extrapyramidal symptoms - Wikipedia

    en.wikipedia.org/wiki/Extrapyramidal_symptoms

    Medications are used to reverse the symptoms of extrapyramidal side effects caused by antipsychotics or other drugs, by either directly or indirectly increasing dopaminergic neurotransmission. The treatment varies by the type of the EPS, but may involve anticholinergic agents such as procyclidine , benztropine , diphenhydramine , and ...

  3. Thermal transmittance - Wikipedia

    en.wikipedia.org/wiki/Thermal_transmittance

    Φ = A × U × (T 1 - T 2) where Φ is the heat transfer in watts, U is the thermal transmittance, T 1 is the temperature on one side of the structure, T 2 is the temperature on the other side of the structure and A is the area in square metres.

  4. Building insulation - Wikipedia

    en.wikipedia.org/wiki/Building_insulation

    The effectiveness of bulk insulation is commonly evaluated by its R-value, of which there are two – metric (SI) (with unit K⋅W −1 ⋅m 2) and US customary (with unit °F⋅ft 2 ⋅h/BTU), the former being 0.176 times the latter numerically, or the reciprocal quantity the thermal conductivity or U-value W⋅K −1 ⋅m −2.

  5. Structural insulated panel - Wikipedia

    en.wikipedia.org/wiki/Structural_insulated_panel

    EPS is the most common of the foams used and has an R-value (thermal resistance) of about 4 °F·ft 2 ·h/Btu (equivalent to about 0.7 K·m 2 /W) per 25 mm thickness, which would give the 3.5 inches (89 mm) of foam in a 4.5-inch-thick (110 mm) panel an R value of 13.8 (caution: extrapolating R-values over thickness may be imprecise due to non ...

  6. Heat transfer coefficient - Wikipedia

    en.wikipedia.org/wiki/Heat_transfer_coefficient

    Architects and engineers call the resulting values either the U-Value or the R-Value of a construction assembly like a wall. Each type of value (R or U) are related as the inverse of each other such that R-Value = 1/U-Value and both are more fully understood through the concept of an overall heat transfer coefficient described in lower section ...

  7. Dynamic insulation - Wikipedia

    en.wikipedia.org/wiki/Dynamic_insulation

    Dynamic insulation works best with a good thickness of insulation so taking 200 mm of cellulose insulation (k = 0.04 W/m °C) the dynamic U value for an air flow of 0.31 mm/s is calculated using equation above to be 0.066 W/m 2 °C. If a lower dynamic U-value is required then a material with lower air permeability than fibreboard would need to ...

  8. External wall insulation - Wikipedia

    en.wikipedia.org/wiki/External_wall_insulation

    External wall insulation systems generally comprise firstly an insulation layer (an element which helps to achieve the requisite thermal performance); and secondly,a protected weatherproof finish (usually a render, although brick slips, [3] tiles, and decorative boards can also be used). Insulating render can also be an advantage in certain ...

  9. Polystyrene - Wikipedia

    en.wikipedia.org/wiki/Polystyrene

    Sheets of EPS are commonly packaged as rigid panels (common in Europe is a size of 100 cm x 50 cm, usually depending on an intended type of connection and glue techniques, it is, in fact, 99.5 cm x 49.5 cm or 98 cm x 48 cm; less common is 120 x 60 cm; size 4 by 8 ft (1.2 by 2.4 m) or 2 by 8 ft (0.61 by 2.44 m) in the United States). Common ...