Search results
Results from the WOW.Com Content Network
7. The change in flow is applied across the loops. For loop 1-2-3, the change in flow is negative so its absolute value is applied in the clockwise direction. For loop 2-3-4, the change in flow is positive so its absolute value is applied in the counter-clockwise direction. For pipe 2-3, which is in both loops, the changes in flow are cumulative.
Pipe expansion joints are necessary in systems that convey high temperature substances such as steam or exhaust gases, or to absorb movement and vibration. A typical joint is a bellows of metal (most commonly stainless steel ), plastic (such as PTFE ), fabric (such as glass fibre) or an elastomer such as rubber .
Orifice plate showing vena contracta. An orifice plate is a thin plate with a hole in it, which is usually placed in a pipe. When a fluid (whether liquid or gaseous) passes through the orifice, its pressure builds up slightly upstream of the orifice [1] but as the fluid is forced to converge to pass through the hole, the velocity increases and the fluid pressure decreases.
Once the friction factors of the pipes are obtained (or calculated from pipe friction laws such as the Darcy-Weisbach equation), we can consider how to calculate the flow rates and head losses on the network. Generally the head losses (potential differences) at each node are neglected, and a solution is sought for the steady-state flows on the ...
The phenomenon of thermal expansion means that a temperature difference will have a corresponding difference in density across the loop. The warmer fluid on one side of the loop is less dense and thus more buoyant than the cooler fluid on the other side. The warmer fluid will "float" above the cooler fluid, and the cooler fluid will "sink ...
Ecology blocks are manufactured using concrete left over from other construction processes. A cross-section of an eco-block typically measures 2 feet (61 cm) square, with block lengths ranging from 3 feet (91 cm) to 6 feet (180 cm). One block weighs between 1,800 pounds (820 kg) and 4,000 pounds (1,800 kg). [1]
Logo of Eurocode 2 An example of a concrete structure. In the Eurocode series of European standards (EN) related to construction, Eurocode 2: Design of concrete structures (abbreviated EN 1992 or, informally, EC 2) specifies technical rules for the design of concrete, reinforced concrete and prestressed concrete structures, using the limit state design philosophy.
In a closed loop system, the heat exchanger is typically coils of high-density polyethylene pipe installed in the ground under or around a building. A heat transfer fluid, usually water or water mixed with antifreeze (propylene glycol, ethanol or methanol), is circulated through this pipe, warming or cooling to the temperature of the earth or ...