enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Current–voltage characteristic - Wikipedia

    en.wikipedia.org/wiki/Current–voltage...

    In this case, the voltage refers to the voltage across a biological membrane, a membrane potential, and the current is the flow of charged ions through channels in this membrane. The current is determined by the conductances of these channels. In the case of ionic current across biological membranes, currents are measured from inside to outside.

  3. Multimeter - Wikipedia

    en.wikipedia.org/wiki/Multimeter

    Analog multimeter Digital multimeter. A multimeter (also known as a volt-ohm-milliammeter, volt-ohmmeter or VOM) [1] is a measuring instrument that can measure multiple electrical properties. [2] [3] A typical multimeter can measure voltage, resistance, and current, [4] in which case can be used as a voltmeter, ohmmeter, and ammeter.

  4. Continuity test - Wikipedia

    en.wikipedia.org/wiki/Continuity_test

    In electronics, a continuity test is the checking of an electric circuit to see if current flows (that it is in fact a complete circuit). A continuity test is performed by placing a small voltage (wired in series with an LED or noise-producing component such as a piezoelectric speaker) across the chosen path.

  5. Current clamp - Wikipedia

    en.wikipedia.org/wiki/Current_clamp

    An electrical meter with integral AC current clamp is known as a clamp meter, clamp-on ammeter, tong tester, or colloquially as an amp clamp. A clamp meter measures the vector sum of the currents flowing in all the conductors passing through the probe, which depends on the phase relationship of the currents. Only one conductor is normally ...

  6. Voltammetry - Wikipedia

    en.wikipedia.org/wiki/Voltammetry

    This graph is used to determine the concentration and the standard potential of the analyte. To determine the concentration, values such as the limiting or peak current are read from the graph and applied to various mathematical models. [10] After determining the concentration, the applied standard potential can be identified using the Nernst ...

  7. Source measure unit - Wikipedia

    en.wikipedia.org/wiki/Source_measure_unit

    The source measure unit (SMU), or source-measurement unit, is an electronic instrument that is capable of both sourcing and measuring at the same time. It can precisely force voltage or current and simultaneously measure precise voltage and/or current. An SMU instrument can source and sink power in all four quadrants.

  8. Voltmeter - Wikipedia

    en.wikipedia.org/wiki/Voltmeter

    For example, a meter with a sensitivity of 1000 ohms per volt would draw 1 milliampere at full scale voltage; if the full scale was 200 volts, the resistance at the instrument's terminals would be 200 000 ohms and at full scale, the meter would draw 1 milliampere from the circuit under test. For multi-range instruments, the input resistance ...

  9. Current loop - Wikipedia

    en.wikipedia.org/wiki/Current_loop

    no current means receive on channel 1, (the default). +6 mA might mean transmit on channel 1; −6 mA might mean stay in receive mode but switch to channel 2. So long as the −6 mA current were present, the remote base station would continue to receive on channel 2. −12 mA might command the base station to transmit on channel 2.