enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Intraocular pressure - Wikipedia

    en.wikipedia.org/wiki/Intraocular_pressure

    Intraocular pressure (IOP) is the fluid pressure inside the eye. Tonometry is the method eye care professionals use to determine this. IOP is an important aspect in the evaluation of patients at risk of glaucoma. [1] Most tonometers are calibrated to measure pressure in millimeters of mercury .

  3. Ocular tonometry - Wikipedia

    en.wikipedia.org/wiki/Ocular_tonometry

    The higher the intraocular pressure, the harder it is to push against and indent the cornea. For very high levels of IOP, extra weights can be added to make the plunger push harder. [14] The movement of the plunger is measured using a calibrated scale. [14] The Schiøtz tonometer is the most common device to use this principle.

  4. Schiøtz tonometer - Wikipedia

    en.wikipedia.org/wiki/Schiøtz_tonometer

    The Schiotz tonometer consists of a curved footplate which is placed on the cornea of a supine patient. A weighted plunger attached to the footplate sinks into the cornea. A scale then gives a reading depending on how much the plunger sinks into the cornea, and a conversion table converts the scale reading into IOP measured in mmHg.

  5. List of instruments used in ophthalmology - Wikipedia

    en.wikipedia.org/wiki/List_of_instruments_used...

    to correct refractive errors of the eye; not invasive Contact lenses: to correct refractive errors of the eye; a little invasive Phoropter: used in refraction testing Tonometers: used to determine the intraoccular pressure (IOP) - useful in glaucoma; video link for various types of tonometers. Speculum: to keep the eyes open during any operation

  6. Intraocular lens power calculation - Wikipedia

    en.wikipedia.org/wiki/Intraocular_lens_power...

    The aim of an accurate intraocular lens power calculation is to provide an intraocular lens (IOL) that fits the specific needs and desires of the individual patient. The development of better instrumentation for measuring the eye's axial length (AL) and the use of more precise mathematical formulas to perform the appropriate calculations have significantly improved the accuracy with which the ...

  7. Corneal pachymetry - Wikipedia

    en.wikipedia.org/wiki/Corneal_pachymetry

    Corneal pachymetry is the process of measuring the thickness of the cornea.A pachymeter is a medical device used to measure the thickness of the eye's cornea.It is used to perform corneal pachymetry prior to refractive surgery, for Keratoconus screening, LRI surgery [1] and is useful in screening for patients suspected of developing glaucoma among other uses.

  8. Snellen chart - Wikipedia

    en.wikipedia.org/wiki/Snellen_chart

    A person taking the test covers one eye from 6 metres or 20 feet away, and reads aloud the letters of each row, beginning at the top. The smallest row that can be read accurately indicates the visual acuity in that specific eye. The symbols on an acuity chart are formally known as "optotypes". Variation of Snellen chart with another letter ...

  9. Optic cup (anatomical) - Wikipedia

    en.wikipedia.org/wiki/Optic_cup_(anatomical)

    The cup-to-disc ratio (often notated CDR) is a measurement used in ophthalmology and optometry to assess the progression of glaucoma. The optic disc is the anatomical location of the eye's "blind spot", the area where the optic nerve leave and blood vessels enter the retina. The optic disc can be flat or it can have a certain amount of normal ...