Explosive boiling can be best described by a p-T phase diagram. [3] Figure on right shows a typical p-T phase diagram of a substance. The binodal line or the coexistence curve is a thermodynamic state where at that specific temperature and pressure, liquid and vapor can coexist.
A three-phase induction motor has a simple design, inherently high starting torque and high efficiency. Such motors are applied in industry for many applications. A three-phase motor is more compact and less costly than a single-phase motor of the same voltage class and rating, and single-phase AC motors above 10 hp (7.5 kW) are uncommon. Three ...
The most common three-phase system will have three hot legs, 208 V to each other and 120 V each to the neutral. An older, but still widely used, high-leg delta system uses three phases with 240 volts phase-to-phase for motor loads, and 120 volts for lighting loads by use of a center-tapped transformer; two of the phases are 120 volts to neutral ...
The maximum voltage rating of IEC 60309 connectors is 1000 V DC or AC; the maximum current rating is 800 A; and the maximum frequency 500 Hz. Plugs are available in P+N+E (unbalanced single phase with neutral), 2P+E (balanced single phase), 3P+E (3 phase without neutral), and 3P+N+E (three phase with neutral).
A typical one-line diagram with annotated power flows. Red boxes represent circuit breakers, grey lines represent three-phase bus and interconnecting conductors, the orange circle represents an electric generator, the green spiral is an inductor, and the three overlapping blue circles represent a double-wound transformer with a tertiary winding.
An exploded-view drawing is a diagram, picture, schematic or technical drawing of an object, that shows the relationship or order of assembly of various parts. [1]It shows the components of an object slightly separated by distance, or suspended in surrounding space in the case of a three-dimensional exploded diagram.
In Europe, three-phase 230/400 V is most commonly used. However, 130/225 V, three-wire, two-phase electric power discontinued systems called B1 are used to run old installations in small groups of houses when only two of the three-phase high-voltage conductors are used. The phase shift in Europe is 120°, as is the case with three-phase current.
For example, balanced two-phase power can be obtained from a three-phase network by using two specially constructed transformers, with taps at 50% and 86.6% of the primary voltage. This Scott T connection produces a true two-phase system with 90° time difference between the phases.