Wave intensity analysis is frequently used in the study of coronary artery hemodynamics where impedance analysis is seldom, if ever, used. [11] It played an important role in the development of the Instantaneous Wave-free Ratio as a measure of the functional effect of stenoses in the coronary arteries. This method informs an interventional ...
Applying spectral Doppler to the renal artery and selected interlobular arteries, peak systolic velocities, resistive index, and acceleration curves can be estimated (Figure 4) (e.g., peak systolic velocity of the renal artery above 180 cm/s is a predictor of renal artery stenosis of more than 60%, and a resistive index, which is a calculated ...
laser Doppler imaging of pulse waves on the surface of the hand by holographic photoplethysmography from on-axis digital interferometry. Principal component analysis of digital holograms [23] reconstructed from digitized interferograms acquired at rates beyond ~1000 frames per second reveals surface waves on the hand. This method is an ...
The arterial resistivity index (also called as Resistance index, abbreviated as RI), developed by Léandre Pourcelot , is a measure of pulsatile blood flow that reflects the resistance to blood flow caused by microvascular bed distal to the site of measurement.
Pulse wave velocity (PWV) is the velocity at which the blood pressure pulse propagates through the circulatory system, usually an artery or a combined length of arteries. [1] PWV is used clinically as a measure of arterial stiffness and can be readily measured non-invasively in humans, with measurement of carotid to femoral PWV (cfPWV) being ...
A Doppler ultrasound blood flow detector, commonly called Doppler wand or Doppler probe, and a sphygmomanometer (blood pressure cuff) are usually needed. The blood pressure cuff is inflated proximal to the artery in question. Measured by the Doppler wand, the inflation continues until the pulse in the artery ceases.
Pseudonormalisation shows a transmitral profile that appears normal. However, with the use of pulmonary vein pulsed wave Doppler, it can be shown that the relaxation pattern is abnormal (systolic blunting, a decrease in the height of the S wave). In addition, performance of a Valsalva manoeuvre will result in unmasking of the pseudonormal state.
In the innominate artery, the average reading is 110/70 mmHg, the right subclavian artery averages 120/80 and the abdominal aorta is 110/70 mmHg. [25] The relatively uniform pressure in the arteries indicate that these blood vessels act as a pressure reservoir for fluids that are transported within them.