enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Insulated glazing - Wikipedia

    en.wikipedia.org/wiki/Insulated_glazing

    A typical installation of insulated glass windows with uPVC frames. Possibly the earliest use of double glazing was in Siberia, where it was observed by Henry Seebohm in 1877 as an established necessity in the Yeniseysk area where the bitterly cold winter temperatures regularly fall below -50 °C, indicating how the concept may have started: [2]

  3. Window insulation - Wikipedia

    en.wikipedia.org/wiki/Window_insulation

    Window insulation reduces heat transfer from one side of a window to the other. The U-value is used to refer to the amount of heat that can pass through a window, called thermal transmittance, with a lower score being better. [1] The U-factor of a window can often be found on the rating label of the window.

  4. Window insulation film - Wikipedia

    en.wikipedia.org/wiki/Window_insulation_film

    One commonly used film is a heat-shrink plastic which is attached to the window frame using double-sided pressure-sensitive tape. A hair dryer is used to remove creases and improve optical clarity. Reduced heat flow also helps prevent condensation [3] [4] [5] which is triggered when the temperature of the inside surface falls below the dew point.

  5. Thermal transmittance - Wikipedia

    en.wikipedia.org/wiki/Thermal_transmittance

    The frame and double sealing of the window system are the actual weak points in the window insulation. Typical thermal transmittance values for common building structures are as follows: [citation needed] Single glazing: 5.7 W/(m 2 ⋅K) Single glazed windows, allowing for frames: 4.5 W/(m 2 ⋅K) Double glazed windows, allowing for frames: 3.3 ...

  6. R-value (insulation) - Wikipedia

    en.wikipedia.org/wiki/R-value_(insulation)

    Installed faced fiberglass batt insulation with its R-value visible (R-21) [1]. The R-value is a measure of how well a two-dimensional barrier, such as a layer of insulation, a window or a complete wall or ceiling, resists the conductive [2] flow of heat, in the context of construction. [3]

  7. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The CLF is the cooling load at a given time compared to the heat gain from earlier in the day. [1] [5] The SC, or shading coefficient, is used widely in the evaluation of heat gain through glass and windows. [1] [5] Finally, the SCL, or solar cooling load factor, accounts for the variables associated with solar heat load.

  8. Heisler chart - Wikipedia

    en.wikipedia.org/wiki/Heisler_Chart

    In thermal engineering, Heisler charts are a graphical analysis tool for the evaluation of heat transfer in transient, one-dimensional conduction. [1] They are a set of two charts per included geometry introduced in 1947 by M. P. Heisler [ 2 ] which were supplemented by a third chart per geometry in 1961 by H. Gröber.

  9. Thermal diffusivity - Wikipedia

    en.wikipedia.org/wiki/Thermal_diffusivity

    In heat transfer analysis, thermal diffusivity is the thermal conductivity divided by density and specific heat capacity at constant pressure. [1] It is a measure of the rate of heat transfer inside a material and has SI units of m 2 /s. It is an intensive property.