A relay Electromechanical relay principle Electromechanical relay schematic showing a control coil, four pairs of normally open and one pair of normally closed contacts An automotive-style miniature relay with the dust cover taken off. A relay is an electrically operated switch. It consists of a set of input terminals for a single or multiple ...
In electric power distribution and transmission, a Buchholz relay is a safety device mounted on some oil-filled power transformers and reactors, equipped with an external overhead oil reservoir called a "conservator". The Buchholz relay is used as a protective device sensitive to the effects of dielectric failure inside the equipment. A generic ...
(from top) Single-pole reed switch, four-pole reed switch and single-pole reed relay. Scale in centimeters. A reed relay [i] is a type of relay that uses an electromagnet to control one or more reed switches. The contacts are of magnetic material and the electromagnet acts directly on them without requiring an armature to move them.
The schematic diagrams for relay logic circuits are often called line diagrams, because the inputs and outputs are essentially drawn in a series of lines. A relay logic circuit is an electrical network consisting of lines, or rungs, in which each line or rung must have continuity to enable the output device. A typical circuit consists of a ...
External Device Monitor (EDM). The device issuing the OSSD signals may have an EDM input. The EDM is used to verify that the controlled device (safety relay) did indeed open when the OSSD signals were dropped. The safety relay has normally closed contacts, which close when the relay is de-energized, thereby turning on the EDM input.
A definite time over-current (DTOC) relay is a relay that operates after a definite period of time once the current exceeds the pickup value. Hence, this relay has current setting range as well as time setting range. An instantaneous over-current relay is an overcurrent relay which has no intentional time delay for operation. The contacts of ...
Protective relay. In utility and industrial electric power transmission and distribution systems, a numerical relay is a computer-based system with software-based protection algorithms for the detection of electrical faults. [1] Such relays are also termed as microprocessor type protective relays.
Normally closed mercury relay, with coil around top of tube and adjustable angle. A mercury relay (mercury displacement relay, mercury contactor) is a relay that uses mercury as the switching element. They are used as high-current switches or contactors, where contact erosion from constant cycling would be a problem for conventional relay contacts.