enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. BS 7671 - Wikipedia

    en.wikipedia.org/wiki/BS_7671

    for AC having a supply frequency of 50, 60 or 400Hz, though the use of other frequencies for special purposes is not excluded. This includes low-voltage installations, as found in most domestic and commercial properties, and extra-low-voltage systems, but excludes high voltage , as found in generation, transmission and distribution networks.

  3. Distribution board - Wikipedia

    en.wikipedia.org/wiki/Distribution_board

    A distribution board (also known as panelboard, circuit breaker panel, breaker panel, electric panel, fuse box or DB box) is a component of an electricity supply system that divides an electrical power feed into subsidiary circuits while providing a protective fuse or circuit breaker for each circuit in a common enclosure.

  4. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    Special wiring rules apply to wet or corrosive locations, [13] and to locations which present an explosion hazard. [14] Wiring materials for use in the United States must generally be made and tested to product standards set by NEMA and Underwriters Laboratories (UL) and must bear approval marks such as those set by UL.

  5. SY control cable - Wikipedia

    en.wikipedia.org/wiki/SY_control_cable

    SY Cables are NOT just for control, and can be used in fixed wiring installations, so long as the specifications are followed, they also have a screen which prevents some EMI) SY cable should not be used in areas exposed to ultraviolet light as it damages the outer sheath leading to cracking and then rusting of the braid as water penetrates the ...

  6. List of IEC standards - Wikipedia

    en.wikipedia.org/wiki/List_of_IEC_standards

    IEC 61554 Panel-Mounted equipment – Electrical measuring instruments – Dimensions for panel mounting IEC 61557 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. – Equipment for testing, measuring or monitoring of protective measures

  7. National Electrical Code - Wikipedia

    en.wikipedia.org/wiki/National_Electrical_Code

    A full-load wire does heat up slightly due to the metallic resistance of the wire, but this wire heating is factored into the cable's temperature rating. (NEC 310.10) [12] The NEC specifies acceptable numbers of conductors in crowded areas such as inside conduit, referred to as the fill rating.

  8. Ring circuit - Wikipedia

    en.wikipedia.org/wiki/Ring_circuit

    The ring circuit is still the most common mains wiring configuration in the UK, although both 20 A and 30 A radial circuits are also permitted by the Wiring Regulations, with a recommendation based on the floor area served (20 A for area up to 25 m 2, 30 A for up to 100 m 2).

  9. Structured cabling - Wikipedia

    en.wikipedia.org/wiki/Structured_cabling

    IP phone systems can run the telephone and the computer on the same wires, eliminating the need for separate phone wiring. Regardless of copper cable type (Cat 5e/6/6A), the maximum distance is 90 m for the permanent link installation, plus an allowance for a combined 10 m of patch cords at the ends.