enow.com Web Search

  1. Ads

    related to: transformer secondary grounding system
    • News

      Check Out The Latest News About

      Maddox Industrial Transformer.

    • Contact Us

      24/7 Service. Get In Touch With Us

      By Phone, Fax Or Email.

    • About Us

      Focused On The Transformer Needs Of

      Industrial & Commercial Clients.

    • Get In Touch

      Contact Us Today

      Have Questions? We're Here To Help

Search results

  1. Results from the WOW.Com Content Network
  2. Grounding transformer - Wikipedia

    en.wikipedia.org/wiki/Grounding_transformer

    A grounding transformer or earthing transformer is a type of auxiliary transformer used in three-phase electric power systems to provide a ground path to either an ungrounded wye or a delta-connected system. [1] [2] Grounding transformers are part of an earthing system of the network. They let three-phase (delta connected) systems accommodate ...

  3. Zigzag transformer - Wikipedia

    en.wikipedia.org/wiki/Zigzag_transformer

    It is used as a grounding transformer, creating a missing neutral connection from an ungrounded 3-phase system to permit the grounding of that neutral to an earth reference point; to perform harmonic mitigation, as they can suppress triplet (3rd, 9th, 15th, 21st, etc.) harmonic currents; [2] to supply 3-phase power as an autotransformer ...

  4. Earthing system - Wikipedia

    en.wikipedia.org/wiki/Earthing_system

    The "local" earth/ground electrode provides "system grounding" [13] at each building where it is installed. The "Grounded" current carrying conductor is the system "neutral". [clarification needed] Australian and New Zealand standards use a modified protective multiple earthing (PME [14]) system called multiple earthed neutral (MEN).

  5. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    Where a delta-fed system must be grounded for detection of stray current to ground or protection from surge voltages, a grounding transformer (usually a zigzag transformer) may be connected to allow ground fault currents to return from any phase to ground. Another variation is a "corner grounded" delta system, which is a closed delta that is ...

  6. High-leg delta - Wikipedia

    en.wikipedia.org/wiki/High-leg_delta

    Center-tapped delta transformer Center-tapped delta transformer voltages. High-leg delta service is supplied in one of two ways. One is by a three-phase transformer (or three single-phase transformers), having four wires coming out of the secondary, the three phases, plus a neutral connected as a center-tap on one of the windings.

  7. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    The system is common in North America for residential and light commercial applications. Two 120 V AC lines are supplied to the premises that are out of phase by 180 degrees with each other (when both measured with respect to the neutral), along with a common neutral. The neutral conductor is connected to ground at the transformer center tap.

  8. Isolation transformer - Wikipedia

    en.wikipedia.org/wiki/Isolation_transformer

    Transformers that have a ratio of 1 to 1 between the primary and secondary windings are often used to protect secondary circuits and individuals from electrical shocks between energized conductors and earth ground. Suitably designed isolation transformers block interference caused by ground loops. Isolation transformers with electrostatic ...

  9. Ground loop (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_loop_(electricity)

    Ground loops can also exist within the internal circuits of electronic equipment, as design flaws. Addition of signal interconnection cables to a system where equipment enclosures are already required to be bonded to ground can create ground loops. Proper design of such a system will satisfy both safety grounding requirements and signal integrity.

  1. Ads

    related to: transformer secondary grounding system