Search results

  1. Results from the WOW.Com Content Network
  2. Building insulation - Wikipedia

    en.wikipedia.org/wiki/Building_insulation

    The Energy Saving Ordinance (EnEV) 2013 clarified the requirement of thermal insulation of the ceiling. And it mentioned that if the ceiling was not fulfilled, thermal insulation will be needed in accessible ceilings over upper floor's heated rooms. [U-Value must be under 0.24 W/(m 2 ⋅K)] [31]

  3. List of insulation materials - Wikipedia

    en.wikipedia.org/wiki/List_of_insulation_materials

    This is a list of insulation materials used around the world. Typical R-values are given for various materials and structures as approximations based on the average of available figures and are sorted by lowest value. R-value at 1 m gives R-values normalised to a 1 metre (3 ft 3 in) thickness and sorts by median value of the range.

  4. Building insulation material - Wikipedia

    en.wikipedia.org/wiki/Building_insulation_material

    It can be used as internal insulation : between studs, joists or ceiling rafters, under timber floors to reduce sound transmittance, against masonry walls or externally : using a rain screen cladding or roofing, or directly plastered/rendered, [24] over timber rafters or studs or masonry structures as external insulation to reduce thermal ...

  5. Spray foam - Wikipedia

    en.wikipedia.org/wiki/Spray_foam

    Spray foam insulation or spray polyurethane foam (SPF) is an alternative to traditional building insulation such as fiberglass. A two-component mixture composed of isocyanate and polyol resin comes together at the tip of a gun, and forms an expanding foam that is sprayed onto roof tiles, concrete slabs, into wall cavities, or through holes ...

  6. Insulating concrete form - Wikipedia

    en.wikipedia.org/wiki/Insulating_concrete_form

    Standard thickness ICF walls have shown sound transmission coefficients (STC) between 46 and 72 compared to 36 for standard fiberglass insulation and drywall. The level of sound attenuation achieved is a function of wall thickness, mass, component materials and air tightness.

  7. R-value (insulation) - Wikipedia

    en.wikipedia.org/wiki/R-value_(insulation)

    Installed faced fiberglass batt insulation with its R-value visible (R-21) [1]. The R-value is a measure of how well a two-dimensional barrier, such as a layer of insulation, a window or a complete wall or ceiling, resists the conductive [2] flow of heat, in the context of construction. [3]

  8. Vapor barrier - Wikipedia

    en.wikipedia.org/wiki/Vapor_barrier

    A slab-on-grade or basement floor should be poured over a cross-laminated polyethylene vapor barrier over 4 inches (10 cm) of granular fill to prevent wicking of moisture from the ground and radon gas incursion. Inside a steel building, water vapor will condense whenever it comes into contact with a surface that is below the dew point temperature.

  9. Structural insulated panel - Wikipedia

    en.wikipedia.org/wiki/Structural_insulated_panel

    EPS is the most common of the foams used and has an R-value (thermal resistance) of about 4 °F·ft 2 ·h/Btu (equivalent to about 0.7 K·m 2 /W) per 25 mm thickness, which would give the 3.5 inches (89 mm) of foam in a 4.5-inch-thick (110 mm) panel an R value of 13.8 (caution: extrapolating R-values over thickness may be imprecise due to non ...