Search results
Results from the WOW.Com Content Network
A hydrostatic test is a way in which pressure vessels such as pipelines, plumbing, gas cylinders, boilers and fuel tanks can be tested for strength and leaks. The test involves filling the vessel or pipe system with a liquid, usually water, which may be dyed to aid in visual leak detection , and pressurization of the vessel to the specified ...
A hydrostatic test involves pressurising the cylinder to its test pressure (usually 5/3 or 3/2 of the working pressure) and measuring its volume before and after the test. A permanent increase in volume above the tolerated level means the cylinder fails the test and must be permanently removed from service. [3]: sect. 5.7.3
Hydrostatic head is also used as a measure of the waterproofing of a fabric, commonly in clothing and equipment used for outdoor recreation.It is measured as a length (typically millimetres), representing the maximum height of a vertical column of water that could be placed on top of the fabric before water started seeping through the weave.
In fluid dynamics, head is a concept that relates the energy in an incompressible fluid to the height of an equivalent static column of that fluid. From Bernoulli's principle, the total energy at a given point in a fluid is the kinetic energy associated with the speed of flow of the fluid, plus energy from static pressure in the fluid, plus energy from the height of the fluid relative to an ...
The burst pressure of this casing is 5020 psi. 1.2 sg brine produces a pressure gradient of 0.52 psi.ft −1 (see Well kill for the mathematical basics of hydrostatic heads). Therefore, the column of brine produces a pressure difference between top and bottom of 2116 psi.
Pressure head is a component of hydraulic head, in which it is combined with elevation head. When considering dynamic (flowing) systems, there is a third term needed: velocity head . Thus, the three terms of velocity head , elevation head , and pressure head appear in the head equation derived from the Bernoulli equation for incompressible fluids :
It works on the principle that the hydrostatic head of the "kill fluid" or "kill mud" will be enough to suppress the pressure of the formation fluids. Well kills may be planned in the case of advanced interventions such as workovers, or be contingency operations. The situation calling for a well kill will dictate the method taken.
p is the hydrostatic pressure (Pa), ρ is the fluid density (kg/m 3), g is gravitational acceleration (m/s 2), z is the height (parallel to the direction of gravity) of the test area (m), 0 is the height of the zero reference point of the pressure (m) p_0 is the hydrostatic pressure field (Pa) along x and y at the zero reference point