Search results

  1. Results from the WOW.Com Content Network
  2. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  3. Ground and neutral - Wikipedia

    en.wikipedia.org/wiki/Ground_and_neutral

    A ground conductor only carries significant current if there is a circuit fault that would otherwise energize exposed conductive parts and present a shock hazard. In that case, circuit protection devices may detect a fault to a grounded metal enclosure and automatically de-energize the circuit, or may provide a warning of a ground fault.

  4. Bootleg ground - Wikipedia

    en.wikipedia.org/wiki/Bootleg_ground

    A receptacle with a bootleg ground. In building wiring installed with separate neutral and protective ground bonding conductors (a TN-S network), a bootleg ground (or a false ground) is a connection between the neutral side of a receptacle or light fixture and the ground lug or enclosure of the wiring device. [1]: 287

  5. Ground (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_(electricity)

    A ground fault protection relay must trip the breaker to protect the circuit before overheating of the resistor occurs. High-resistance grounding (HRG) systems use an NGR to limit the fault current to 25 A or less. They have a continuous rating, and are designed to operate with a single-ground fault.

  6. Electrical wiring - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring

    Each phase of the circuit is run in a separate grounded metal enclosure. The only fault possible is a phase-to-ground fault, since the enclosures are separated. This type of bus can be rated up to 50,000 amperes and up to hundreds of kilovolts (during normal service, not just for faults), but is not used for building wiring in the conventional ...

  7. Electrical fault - Wikipedia

    en.wikipedia.org/wiki/Electrical_fault

    In an electric power system, a fault or fault current is any abnormal electric current. For example, a short circuit is a fault in which a live wire touches a neutral or ground wire. An open-circuit fault occurs if a circuit is interrupted by a failure of a current-carrying wire (phase or neutral) or a blown fuse or circuit breaker.

  8. Earth-leakage circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Earth-leakage_circuit_breaker

    An earth-leakage circuit breaker (ELCB) is a safety device used in electrical installations to prevent shock. It consists of either a current sensing mechanism, or a voltage sensing mechanism. Such a protection mechanism may be found in the form of distribution board modules, standalone devices, and special sockets (aka receptacles ).

  9. Floating ground - Wikipedia

    en.wikipedia.org/wiki/Floating_ground

    Electrical equipment may be designed with a floating ground for one of several reasons. One is safety. For example, a low-voltage DC power supply, such as a mobile phone charger, is connected to the mains through a transformer of one type or another, and there is no direct electrical connection between the current return path on the low-voltage side and physical ground (earth).