Entitled ‘Rules and Regulations for the prevention of Fire Risks Arising from Electric Lighting’, and known as the "Wiring Rules". Two core cable, line and neutral, no earth. Protection was a re-wirable fuse. 1888: 2nd: IEE: Entitled 'Wiring Rules & Regulations in Buildings. [verification needed] 1897: 3rd: IEE
IEC 60364 Electrical Installations for Buildings is the International Electrotechnical Commission (IEC)'s international standard on electrical installations of buildings.This standard is an attempt to harmonize national wiring standards in an IEC standard and is published in the European Union by CENELEC as "HD 60364".
With transparent cord the hot wire is copper colored, and the neutral is silver colored. Grounding wire of circuit may be bare or identified insulated wire of green or green having yellow stripes. All metallic systems in a building are to be bonded to the building grounding system, such as water, natural gas, HVAC piping, and others.
All-copper building wiring refers to buildings in which the inside electrical service is carried exclusively over copper wiring. In all-copper homes, copper conductors are used in circuit breaker panels, branch circuit wiring (to outlets, switches, lighting fixtures and the like), and in dedicated branches serving heavy-load appliances (such as ...
An electrical code is a term for a set of regulations for the design and installation of electrical wiring in a building. The intention of such regulations is to provide standards to ensure electrical wiring systems are safe for people and property, protecting them from electrical shock and fire hazards. They are usually based on a model code ...
A somewhat similar system called "concentric wiring" was introduced in the United States around 1905. In this system, an insulated electrical wire was wrapped with copper tape which was then soldered, forming the grounded (return) conductor of the wiring system. The bare metal sheath, at earth potential, was considered safe to touch.
Prior to 1972, however, the aluminum wire used was manufactured to conform to the 1350 series aluminum alloy, but this alloy was eventually deemed unsuitable for branch circuits due to galvanic corrosion where the copper and aluminum touched, resulting in poor contact and resistance to current flow, connector overheating problems, and potential ...
Such systems typically run between 100 and 500 volts, however their classifications and specifications vary greatly by geographical area (see Mains electricity by country). Mains power is typically distributed through insulated copper wire concealed in the building's subfloor, wall cavities and ceiling cavity.