enow.com Web Search

  1. Ads

    related to: pros and cons of an inverter generator installation checklist
  2. zoro.com has been visited by 1M+ users in the past month

Search results

  1. Results from the WOW.Com Content Network
  2. Inverter-based resource - Wikipedia

    en.wikipedia.org/wiki/Inverter-based_resource

    An inverter-based resource (IBR) is a source of electricity that is asynchronously connected to the electrical grid via an electronic power converter ("inverter"). The devices in this category, also known as converter interfaced generation (CIG), include the variable renewable energy generators (wind, solar) and battery storage power stations. [1]

  3. Single-wire earth return - Wikipedia

    en.wikipedia.org/wiki/Single-wire_earth_return

    SWER is promoted as safe due to isolation of the ground from both the generator and user. Most other electrical systems use a metallic neutral connected directly to the generator or a shared ground. [3] Grounding is critical. Significant currents on the order of 8 amperes flow through the ground near the earth points.

  4. Grid-tie inverter - Wikipedia

    en.wikipedia.org/wiki/Grid-tie_inverter

    A grid-tie inverter converts direct current (DC) into an alternating current (AC) suitable for injecting into an electrical power grid, at the same voltage and frequency of that power grid. Grid-tie inverters are used between local electrical power generators: solar panel , wind turbine , hydro-electric , and the grid.

  5. Isolated-phase bus - Wikipedia

    en.wikipedia.org/wiki/Isolated-phase_bus

    The consequences of a two- or three-phase fault between the generator and the first circuit breaker are therefore much more serious and often result in severe damage to the busbars and nearby equipment. Isolated-phase bus is made in ratings from 3000 amperes to 45,000 amperes, and rated for voltages from 5000 volts up to about 35,000 volts.

  6. Doubly fed electric machine - Wikipedia

    en.wikipedia.org/wiki/Doubly_fed_electric_machine

    The doubly fed generator rotors are typically wound with 2 to 3 times the number of turns of the stator. This means that the rotor voltages will be higher and currents respectively lower. Thus in the typical ±30% operational speed range around the synchronous speed, the rated current of the converter is accordingly lower which leads to a lower ...

  7. Synchronization (alternating current) - Wikipedia

    en.wikipedia.org/wiki/Synchronization...

    During installation of a generator, careful checks are made to ensure the generator terminals and all control wiring is correct so that the order of phases (phase sequence) matches the system. Connecting a generator with the wrong phase sequence will result in large, possibly damaging, currents as the system voltages are opposite to those of ...

  8. Induction generator - Wikipedia

    en.wikipedia.org/wiki/Induction_generator

    An induction generator or asynchronous generator is a type of alternating current (AC) electrical generator that uses the principles of induction motors to produce electric power. Induction generators operate by mechanically turning their rotors faster than synchronous speed.

  9. Magnetohydrodynamic generator - Wikipedia

    en.wikipedia.org/wiki/Magnetohydrodynamic_generator

    The Faraday generator is named for Michael Faraday's experiments on moving charged particles in the Thames River. A simple Faraday generator consists of a wedge-shaped pipe or tube of some non-conductive material. When an electrically conductive fluid flows through the tube, in the presence of a significant perpendicular magnetic field, a ...

  1. Ads

    related to: pros and cons of an inverter generator installation checklist