enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Tap changer - Wikipedia

    en.wikipedia.org/wiki/Tap_changer

    However, a transformer may include a tap changer on each winding if there are advantages to do so. For example, in power distribution networks, a large step-down transformer may have an off-load tap changer on the primary winding and an on load automatic tap changer on the secondary winding or windings. The high voltage tap is set to match long ...

  3. Tap converter - Wikipedia

    en.wikipedia.org/wiki/Tap_converter

    Both linear spacing and power-of-two-style Vernier spacing can be employed in establishing the tap positions, e.g., a four-tap transformer can provide taps at 0.25, 0.5, 0.75, 1.0 (linear) or 0.0625, 0.125, 0.25, and 0.5 (Vernier). (The limitations of the Vernier—in this case, that the maximum obtainable amplitude is 0.9375—are less ...

  4. Voltage regulation - Wikipedia

    en.wikipedia.org/wiki/Voltage_regulation

    a load tap changer (LTC) at the substation transformer, which changes the turns ratio in response to load current and thereby adjusts the voltage supplied at the sending end of the feeder; voltage regulators , which are essentially transformers with tap changers to adjust the voltage along the feeder, so as to compensate for the voltage drop ...

  5. Rapid voltage change - Wikipedia

    en.wikipedia.org/wiki/Rapid_voltage_change

    A rapid voltage change or RVC is one of the power-quality (PQ) issue related to voltage disturbance. "According to IEC 61000-4-30, Ed. 3 standard, RVC is defined as "a quick transition in root means square (r.m.s.) voltage occurring between two steady-state conditions, and during which the r.m.s. voltage does not exceed the dip/swell thresholds."

  6. Variable shunt reactor - Wikipedia

    en.wikipedia.org/wiki/Variable_shunt_reactor

    The rating of a VSR can be changed in steps: the maximum regulation range depends on the capability of the on-load tap changer used in combination with the regulation winding used for the shunt reactor. The maximum regulation range has increased over the years, [1] from 50%, up to 80% at some voltage levels. [2]

  7. AOL Mail

    mail.aol.com

    Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!

  8. Distribution transformer - Wikipedia

    en.wikipedia.org/wiki/Distribution_transformer

    Transformers designed for below-grade installation can be designed for periodic submersion in water. [14] Distribution transformers may include an off-load tap changer, which slightly adjusts the ratio between primary and secondary voltage to bring the customer's voltage within the desired range on long or heavily loaded lines. [citation needed]

  9. Center tap - Wikipedia

    en.wikipedia.org/wiki/Center_tap

    For example, a 24 VCT transformer will measure 24 VAC across the outer two taps (winding as a whole), and 12 VAC from each outer tap to the center-tap (half winding). These two 12 VAC supplies are 180 degrees out of phase with each other, measured with respect to the tap, thus making it easy to derive positive and negative 12 volt DC power ...