Nominal Pipe Size (NPS) is a North American set of standard sizes for pipes used for high or low pressures and temperatures. [1] " Nominal" refers to pipe in non-specific terms and identifies the diameter of the hole with a non-dimensional number (for example – 2-inch nominal steel pipe" consists of many varieties of steel pipe with the only criterion being a 2.375-inch (60.3 mm) outside ...
A Fixture Unit is not a flow rate unit but a design factor. A fixture unit is equal to 1 cubic foot (0.028 m 3) of water drained in a 1 + 1 ⁄ 4 inches (32 mm) diameter pipe over one minute. [2] One cubic foot of water is roughly 7.48 US gallons (28.3 L; 6.23 imp gal). A Fixture Unit is used in plumbing design for both water supply and waste ...
A sewer pipe is normally at neutral air pressure compared to the surrounding atmosphere.When a column of waste water flows through a pipe, it compresses air ahead of it in the system, creating a positive pressure that must be released so it does not push back on the waste stream and downstream traps, slow drainage, and induce potential clogs.
A reducer reduces the pipe size from a larger to a smaller bore (inner diameter). Alternatively, reducer may refer to any fitting which causes a change in pipe diameter. [15] This change may be intended to meet hydraulic flow requirements of the system or adapt to existing piping of a different size. The reduction length is usually equal to the ...
In North America and the UK, pressure piping is usually specified by Nominal Pipe Size (NPS) and schedule (SCH). Pipe sizes are documented by a number of standards, including API 5L, ANSI/ASME B36.10M (Table 1) in the US, and BS 1600 and BS 1387 in the United Kingdom. Typically the pipe wall thickness is the controlled variable, and the Inside ...
The difference between pipes and tubes is a matter of sizing. For instance, PVC pipe for plumbing applications and galvanized steel pipe are measured in iron pipe size (IPS). Copper tube, CPVC, PeX and other tubing is measured nominally, basically an average diameter. These sizing schemes allow for universal adaptation of transitional fittings.
In shop drawings pipe sizes should be marked with the text and size should be shown with double line. Each pipes with different purposes will be displayed with different colors for ease of understanding. Drainage pipes should be shown with slope. For water supply, pump capacity and number of pumps will be attached as drawing file.
Section 3 does not allow any construction approval of the Inspector of Plumbing and Drainage. A written description of the proposed work is to be submitted in advance to the inspector for his approval. Section 16 mandates the use of cast iron for interior pipes and Section 12 mandates the use of "vitrified stone ware pipes" that "run under ...