Single-wire earth return (SWER) or single-wire ground return is a single-wire transmission line which supplies single-phase electric power from an electrical grid to remote areas at lowest cost. The earth (or sometimes a body of water) is used as the return path for the current, to avoid the need for a second wire (or neutral wire ) to act as a ...
Earth-return telegraph is the system whereby the return path for the electric current of a telegraph circuit is provided by connection to the earth through an earth electrode. Using earth return saves a great deal of money on installation costs since it halves the amount of wire that is required, with a corresponding saving on the labour ...
The single-wire transmission line is not the same as the single-wire earth return system, which is not covered in this article. The latter system relies on a return current through the ground, using the earth as a second conductor between ground terminal electrodes. In a single-wire transmission line there is no second conductor of any form.
In North America, overhead distribution systems may be three phase, four wire, with a neutral conductor. Rural distribution system may have long runs of one phase conductor and a neutral. [17] In other countries or in extreme rural areas the neutral wire is connected to the ground to use that as a return (single-wire earth return).
A transmission line is drawn as two black wires. At a distance x into the line, there is current I(x) travelling through each wire, and there is a voltage difference V(x) between the wires. If the current and voltage come from a single wave (with no reflection), then V(x) / I(x) = Z 0, where Z 0 is the characteristic impedance of the line.
Earth return or ground return is an electric circuit using the earth for one conductor. It may refer to: Earth-return telegraph; Single-wire earth return, an electric power distribution system; Simplex signaling, an earth return signalling system used in telephony
Important examples of these single-wire systems were the Morse telegraph (1837) and the Cooke & Wheatstone single-needle telegraph (1843). In such systems the cost of a return conductor was fully 50 per cent of the cable costs. It was discovered that a return conductor could be replaced with a return path through the Earth using grounding ...
The term "stray voltage" is used for the gradient (rate of change with respect to distance) of electrical potential in the surface of the soil, associated with single-wire earth return electricity distribution systems used in some rural locations. This gradient is low at points far away from the earth return connections, but increases near the ...