Coded panels were the earliest type of central fire alarm control, and were made during the 1800s to the 1970s. A coded panel is similar in many ways to a modern conventional panel (described below), except each zone was connected to its own code wheel, which, depending on the way the panel was set up, would either do sets of four rounds of code until the initiating pull station was reset ...
A fire alarm control panel Fire alarm speaker and pull station. Fire alarm systems are composed of several distinct parts: Fire alarm control panel (FACP), or fire alarm control unit (FACU): This component, the hub of the system, monitors inputs and system integrity, controls outputs, and transmits information.
The alarm transmission methods covered under UL 365 can be categorized under standard line security or encrypted line security. The systems are required to operate within the limits of Class 2 remote control and signal circuits as defined by the National Electrical Code, NFPA 70.
The EN 54 series of standards covers the following topics and product groups related to fire detection and fire alarm systems: [6] [7] Introduction: the introduction to the series of standards contains a diagram of a fire alarm system as well as numerous definitions of terms that are used in the other parts of the series of standards.
Commercial smoke detectors are either conventional or addressable, and are connected to security alarm or fire alarm systems controlled by fire alarm control panels (FACP). [56] These are the most common type of detector and are usually significantly more expensive than single-station battery-operated residential smoke alarms. [56]
Many modern fire alarm pull stations are single-action and only require the user to pull down a handle to sound the alarm. Other fire alarm pull stations are dual-action, and as such require the user to perform a second task before pulling down, such as lifting or pushing in a panel on the station or breaking a glass panel with an attached hammer.
Discover the latest breaking news in the U.S. and around the world — politics, weather, entertainment, lifestyle, finance, sports and much more.
Fire-Lite was the first company to introduce a compact, inexpensive addressable fire alarm control panel. [2] Some of their recognizable products include the Fire-Lite BG-10 pull station, introduced in 1983, and the newer BG-12 pull station, introduced in 1999. Fire-Lite is part of the Honeywell Life Safety Group, along with Notifier.