A blood gas test or blood gas analysis tests blood to measure blood gas tension values, it also measures blood pH, and the level and base excess of bicarbonate.The source of the blood is reflected in the name of each test; arterial blood gases come from arteries, venous blood gases come from veins and capillary blood gases come from capillaries. [1]
Once the sample is obtained, [7] care is taken to eliminate visible gas bubbles, as these bubbles can dissolve into the sample and cause inaccurate results. The sealed syringe is taken to a blood gas analyzer. [8] If a plastic blood gas syringe is used, the sample should be transported and kept at room temperature and analyzed within 30 min.
Finger tip carboxyhemoglobin saturation monitor.. A CO-oximeter is a device that measures the oxygen carrying state of hemoglobin in a blood specimen, including oxygen-carrying hemoglobin (O2Hb), non-oxygen-carrying but normal hemoglobin (HHb) (formerly, but incorrectly, referred to as 'reduced' hemoglobin), as well as the dyshemoglobins such as carboxyhemoglobin (COHb) and methemoglobin (MetHb).
Arterial lines are most commonly used in intensive care medicine and anesthesia to monitor blood pressure directly and in real-time (rather than by intermittent and indirect measurement) and to obtain samples for arterial blood gas analysis.
This helps to determine the degree of any problems with how the lungs transfer oxygen to the blood. [5] A sample of arterial blood is collected for this test. [6] With a normal P a O 2 of 60–100 mmHg and an oxygen content of F I O 2 of 0.21 of room air, a normal P a O 2 /F I O 2 ratio ranges between 300 and 500 mmHg.
In healthy individuals, the difference between arterial blood and expired gas CO 2 partial pressures is very small (normal difference 4-5 mmHg). In the presence of most forms of lung disease, and some forms of congenital heart disease (the cyanotic lesions) the difference between arterial blood and expired gas increases which can be an ...
Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!
This test involves measuring the partial pressure difference between inspired and expired carbon monoxide. It relies on the strong affinity and large absorption capacity of red blood cells for carbon monoxide and thus demonstrates gas uptake by the capillaries that are less dependent on cardiac output . [ 3 ]