The two most common are those sized for standard electrical knockout sizes and those that are for true dimensional holes. A 3/4 inch conduit size punch actually punches a hole that is approximately 1.1 inches diameter for 3/4 nominal size conduit. A dimensional size punch makes a hole very close to the indicated size.
Galvanized rigid conduit (GRC) is galvanized steel tubing, with a tubing wall that is thick enough to allow it to be threaded. Its common applications are in commercial and industrial construction. [1] It is designed to protect wire and connectors. Intermediate metal conduit (IMC) is a steel tubing heavier than EMT but lighter than RMC. It may ...
Lineman's pliers have a tapered nose suitable for reaming the rough edge of a 1 ⁄ 2-inch (13 mm) or larger conduit, or cleaning sharp metal from the inside of a standard metal knockout in an electrical enclosure such as a junction box or breaker panel. Some brands manufacture pliers (i.e. Ideal) with a narrower jaw, suitable for reaming out ...
Nominal Pipe Size (NPS) is a North American set of standard sizes for pipes used for high or low pressures and temperatures. [1] " Nominal" refers to pipe in non-specific terms and identifies the diameter of the hole with a non-dimensional number (for example – 2-inch nominal steel pipe" consists of many varieties of steel pipe with the only criterion being a 2.375-inch (60.3 mm) outside ...
The NEC specifies acceptable numbers of conductors in crowded areas such as inside conduit, referred to as the fill rating. If the accepted fill rating is exceeded, then all the cables in the conduit are derated, lowering their acceptable maximum ambient operating temperature. Derating is necessary because multiple conductors carrying full-load ...
Twist-on wire connectors are commonly color-coded to indicate the connector size and, hence, their capacity. They are commonly used as an alternative to terminal blocks or soldering of conductors, since they are quicker to install and, unlike soldered or crimped connections, allow easy subsequent removal for future modifications.
In commerce, the sizes of wire are estimated by devices, also called gauges, which consist of plates of circular or oblong form having notches of different widths around their edges to receive wire and sheet metals of different thicknesses. Each notch is stamped with a number, and the wire or sheet, which just fits a given notch, is stated to ...
While larger sizes are still used to feed power to electrical panels and large devices, aluminium wiring for residential use has acquired a poor reputation and has fallen out of favour. Aluminium conductors are still heavily used for bulk power transmission , power distribution , and large feeder circuits with heavy current loads, due to the ...