    The Hemopump was designed to allow for temporary support of a failing heart. It is a continuous flow pump, and does not need to be synced to the rhythm of the heart. It assists in temporary heart stimulation with conditions such as cardiogenic shock following acute myocardial infarction, heart failure from cardiopulmonary bypass, and more.

  3. Ventricular assist device - Wikipedia

    en.wikipedia.org/wiki/Ventricular_assist_device

    The LVAD is the most common device applied to a defective heart (it is sufficient in most cases; the right side of the heart is then often able to make use of the heavily increased blood flow), but when the pulmonary arterial resistance is high, then an (additional) right ventricular assist device (RVAD) might be necessary to resolve the ...

  4. Protected percutaneous coronary intervention - Wikipedia

    en.wikipedia.org/wiki/Protected_percutaneous...

    During a protected percutaneous coronary intervention (Protected PCI) procedure, "the Impella 2.5 heart pump helps maintain a stable heart function by pumping blood for the heart. This gives a weak heart muscle an opportunity to rest and reduces the heart’s workload, preventing the heart from being overstressed by the procedure as coronary ...

  5. Impella - Wikipedia

    en.wikipedia.org/wiki/Impella

    Impella heart pumps are percutaneous microaxial pumps that act as mechanical circulatory support devices in patients in need of hemodynamic support. [11] The pumps are mounted on support catheters and typically inserted through the femoral artery, although axillary and subclavian artery approaches are not uncommon. [12]

  6. Cardiac contractility modulation - Wikipedia

    en.wikipedia.org/wiki/Cardiac_contractility...

    The FDA approved the OPTIMIZER Smart System, which delivers cardiac contractility modulation therapy, as indicated to improve 6-minute hall walk distance, quality of life, and functional status of NYHA Class III heart failure patients who remain symptomatic despite guideline directed medical therapy, who are in normal sinus rhythm, are not indicated for cardiac resynchronization therapy, and ...

  7. Intra-aortic balloon pump - Wikipedia

    en.wikipedia.org/wiki/Intra-aortic_balloon_pump

    The intra-aortic balloon pump (IABP) is a mechanical device that increases myocardial oxygen perfusion and indirectly increases cardiac output through afterload reduction. It consists of a cylindrical polyurethane balloon that sits in the aorta , approximately 2 centimeters (0.79 in) from the left subclavian artery . [ 1 ]

  8. AOL Mail

    mail.aol.com

    Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!

  9. Thoratec - Wikipedia

    en.wikipedia.org/wiki/Thoratec

    With the 2001 Thermo Cardiosystems merger, Thoratec acquired the HeartMate Left Ventricular Assist System, an implanted VAD for end-stage heart patients. A landmark three-year study of 129 patients at 22 major medical centers, called REMATCH (Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure) and published in November 2001, found that the HeartMate VE ...