enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Hexaxial reference system - Wikipedia

    en.wikipedia.org/wiki/Hexaxial_reference_system

    The hexaxial reference system is a diagram that is used to determine the heart's electrical axis in the frontal plane. The hexaxial reference system, better known as the Cabrera system, is a convention to present the extremity leads of the 12 lead electrocardiogram, [1] that provides an illustrative logical sequence that helps interpretation of the ECG, especially to determine the heart's ...

  3. Lewis lead - Wikipedia

    en.wikipedia.org/wiki/Lewis_lead

    A Lewis Lead (also called the S5 lead) is a modified ECG lead used to detect atrial flutter waves when atrial flutter is suspected clinically, based on signs and symptoms, but is not definitely demonstrated on the standard 12 lead ECG. In order to create the Lewis Lead, the right arm electrode is moved to the manubrium adjacent to the sternum ...

  4. Einthoven's triangle - Wikipedia

    en.wikipedia.org/wiki/Einthoven's_triangle

    Lead II — This axis goes from the right arm to the left leg, with the negative electrode on the shoulder and the positive one on the leg. This results in a +60 degree angle of orientation. [4] = Lead III — This axis goes from the left shoulder (negative electrode) to the right or left leg (positive electrode). This results in a +120 degree ...

  5. File:ECGcolor.svg - Wikipedia

    en.wikipedia.org/wiki/File:ECGcolor.svg

    Printable version; Page information; ... Diagram showing the connection of ECG leads. Date: 5 March 2009 (upload date) ... 12-lead ECG lead placement diagram.

  6. Axillary lines - Wikipedia

    en.wikipedia.org/wiki/Axillary_lines

    The V 5 ECG lead is placed on the anterior axillary line, horizontally even with V 4. The midaxillary line is a coronal line on the torso between the anterior and posterior axillary lines. It is a landmark used in thoracentesis , [ 2 ] and the V6 electrode of the 10 electrode ECG.

  7. Electrocardiography - Wikipedia

    en.wikipedia.org/wiki/Electrocardiography

    In a 12-lead ECG, all leads except the limb leads are assumed to be unipolar (aVR, aVL, aVF, V 1, V 2, V 3, V 4, V 5, and V 6). The measurement of a voltage requires two contacts and so, electrically, the unipolar leads are measured from the common lead (negative) and the unipolar lead (positive).

  8. Advanced emergency medical technician - Wikipedia

    en.wikipedia.org/wiki/Advanced_emergency_medical...

    EMT-advanced in the state of Maine can provide many different treatments including IV therapy, EKG monitoring, 12 lead EKG placement (however, an EMT-paramedic must interpret the cardiac rhythm), dextrose (D50), glucagon, and other medications. Advanced EMTs can also place laryngeal mask airway devices and use CPAP when needed. Some treatments ...

  9. Bruce protocol - Wikipedia

    en.wikipedia.org/wiki/Bruce_protocol

    The leads of the ECG are placed on the chest wall. The treadmill is started at 2.74 km/h (1.7mph) & at an inclined gradient of 10%. After 3 min incline of the treadmill is increased by 2%, and the speed increases.