Ocular hypertension is the presence of elevated fluid pressure inside the eye (intraocular pressure), usually with no optic nerve damage or visual field loss. [1] [2]For most individuals, the normal range of intraocular pressure is between 10 mmHg and 21 mmHg. [3]
Intraocular pressure (IOP) is the fluid pressure inside the eye. Tonometry is the method eye care professionals use to determine this. IOP is an important aspect in the evaluation of patients at risk of glaucoma. [1] Most tonometers are calibrated to measure pressure in millimeters of mercury .
The higher the intraocular pressure, the harder it is to push against and indent the cornea. For very high levels of IOP, extra weights can be added to make the plunger push harder. [14] The movement of the plunger is measured using a calibrated scale. [14] The Schiøtz tonometer is the most common device to use this principle.
For eye pressures, a value of 28 hPa (21 mmHg) above atmospheric pressure 1,010 hPa (760 mmHg) is often used, with higher pressures leading to a greater risk. [2] [26] However, some may have high eye pressure for years and never develop damage. [2] Conversely, optic nerve damage may occur with normal pressure, known as normal-tension glaucoma. [27]
The Schiotz tonometer consists of a curved footplate which is placed on the cornea of a supine patient. A weighted plunger attached to the footplate sinks into the cornea. A scale then gives a reading depending on how much the plunger sinks into the cornea, and a conversion table converts the scale reading into IOP measured in mmHg.
He also recommends having both feet on the ground and yours eyes closed during the reading. Regarding ideal numbers, the famous M.D. says: "Your blood pressure is supposed to be under 140 over 90 ...
Pressure is applied to the cornea until the inner edges of two semicircular fluorescein mires come into contact, forming a continuous circle. The corresponding reading on the tonometer scale represents the IOP of the measured eye. Intraocular pressure (IOP) can be measured by tonometry devices. The eye can be thought of as an enclosed ...
Normal wearing time o symptoms Zero symptoms ϕ Horizontal orthophoria θ Vertical orthophoria ⊕ Horizontal and vertical orthophoria OC's Optical centres Occ. Occupation OD oculus dexter (right eye) OH Ocular history OMB Oculo motor balance ONH Optic nerve head Oph Ophthalmoscopy OS oculus sinister (left eye) OU oculus uterque (both eyes) PD