Search results
Results from the WOW.Com Content Network
The study of the behavior of air-water vapor mixtures. Water vapor plays an important role in energy transfer and human comfort in HVAC design. rooftop unit (RTU) A packaged unit that controls both heating and air conditioning. An air handler typically refers to a unit that provides a fan to support either heating or cooling. radiant ceiling panels
The amount of water vapor that can be stored in the air can be increased simply by increasing the temperature. [8] However, this can be a double edged sword as most condensation in the home occurs when warm, moisture heavy air comes into contact with a cool surface. As the air is cooled, it can no longer hold as much water vapor.
Air conditioning, often abbreviated as A/C (US) or air con (UK), [1] is the process of removing heat from an enclosed space to achieve a more comfortable interior temperature (sometimes referred to as 'comfort cooling') and in some cases also strictly controlling the humidity of internal air.
An air conditioning system, or a standalone air conditioner, provides cooling and/or humidity control for all or part of a building. Air conditioned buildings often have sealed windows, because open windows would work against the system intended to maintain constant indoor air conditions.
Interstitial condensation is a type of condensation that may occur within an enclosed wall, roof or floor cavity structure, which can create dampening.. When moisture-laden air at dew point temperature penetrates inside a cavity of the structure, it condenses into liquid water on that surface.
Absolute humidity is defined as water mass per volume of air. A given mass of air will grow or shrink as the temperature or pressure varies. So the absolute humidity of a mass of air will vary due to changes in temperature or pressure, even when the proportion of water in that mass of air (its specific humidity) remains constant.
The dimensionless humidity ratio is typically expressed as grams of water per kilogram of dry air, or grains of water per pound of air (7000 grains equal 1 pound). Specific enthalpy, symbolized by h, is the sum of the internal (heat) energy of the moist air in question, including the heat of the air and water vapor within. Also called heat ...
Moisture Removal Efficiency (MRE) is a measure of the energy efficiency of any dehumidification process. Moisture removal efficiency is the water vapor removed from air at a defined inlet air temperature and humidity, divided by the total energy consumed by the dehumidification equipment during the same time period, including all fan and pump ...