enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Life-cycle assessment - Wikipedia

    en.wikipedia.org/wiki/Life-cycle_assessment

    Life cycle inventory analysis is followed by a life cycle impact assessment (LCIA). This phase of LCA is aimed at evaluating the potential environmental and human health impacts resulting from the elementary flows determined in the LCI. The ISO 14040 and 14044 standards require the following mandatory steps for completing an LCIA: [52] [53] [54]

  3. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    For example, balanced two-phase power can be obtained from a three-phase network by using two specially constructed transformers, with taps at 50% and 86.6% of the primary voltage. This Scott T connection produces a true two-phase system with 90° time difference between the phases.

  4. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    A three-phase induction motor has a simple design, inherently high starting torque and high efficiency. Such motors are applied in industry for many applications. A three-phase motor is more compact and less costly than a single-phase motor of the same voltage class and rating, and single-phase AC motors above 10 hp (7.5 kW) are uncommon. Three ...

  5. Phase diagram - Wikipedia

    en.wikipedia.org/wiki/Phase_diagram

    The phase diagram shows, in pressure–temperature space, the lines of equilibrium or phase boundaries between the three phases of solid, liquid, and gas. The curves on the phase diagram show the points where the free energy (and other derived properties) becomes non-analytic: their derivatives with respect to the coordinates (temperature and ...

  6. CALPHAD - Wikipedia

    en.wikipedia.org/wiki/CALPHAD

    CALPHAD stands for Computer Coupling of Phase Diagrams and Thermochemistry, a methodology introduced in 1970 by Larry Kaufman, originally known as CALculation of PHAse Diagrams. [1] [2] [3] An equilibrium phase diagram is usually a diagram with axes for temperature and composition of a chemical system. It shows the regions where substances or ...

  7. Vector group - Wikipedia

    en.wikipedia.org/wiki/Vector_group

    Phase rotation is always counterclockwise (internationally adopted convention) and indicates multiples of 30 degree lag for low voltage winding using of the high voltage winding as the reference. Thus 1 = 30°, 2 = 60°, 3 = 90°, 6 = 180° and 12 = 0° or 360°. According to the IEC60076-1 standard, the notation is HV-LV in sequence.

  8. High-leg delta - Wikipedia

    en.wikipedia.org/wiki/High-leg_delta

    High-leg delta (also known as wild-leg, stinger leg, bastard leg, high-leg, orange-leg, red-leg, dog-leg delta) is a type of electrical service connection for three-phase electric power installations. It is used when both single and three-phase power is desired to be supplied from a three phase transformer (or transformer bank).

  9. Triple phase boundary - Wikipedia

    en.wikipedia.org/wiki/Triple_phase_boundary

    A triple phase boundary (TPB) is a geometrical class of phase boundary and the location of contact between three different phases.A simple example of a TPB is a coastline where land, air and sea meet to create an energetic location driven by solar, wind and wave energy capable of supporting a high level of biodiversity.