A thermal switch (sometimes thermal reset or thermal cutout (TCO)) is a device which normally opens at a high temperature (often with a faint "plink" sound) and re-closes when the temperature drops. The thermal switch may be a bimetallic strip, often encased in a tubular glass bulb to protect it from dust or short circuit. Another common design ...
A limit switch with a roller-lever operator; this is installed on a gate on a canal lock, and indicates the position of a gate to a control system A limit switch mounted on a moving part of a bridge In electrical engineering , a limit switch is a switch operated by the motion of a machine part or the presence of an object.
A sail switch, vane switch or flow switch is a mechanical switch that is actuated on or off in response to the flow or non-flow of a fluid such as air or water. [1] A sail switch typically operates through the use of a paddle or a diaphragm which gets displaced due to the force of fluid or air moving past it.
Consequently, they are generally chosen for lower power circuitry, where the additional ongoing power waste is minor. Inrush limiting resistors are much cheaper than thermistors. They are found in most compact fluorescent lamps (light bulbs). They can be switched out of the circuit using a relay or MOSFET after inrush current is complete.
A Single-Pole, Single-Throw (SPST) mercury switch on millimetre graph paper, device length approximately 1.5 cm Another mercury switch design. A mercury switch is an electrical switch that opens and closes a circuit when a small amount of the liquid metal mercury connects metal electrodes to close the circuit. There are several different basic ...
Start draft inducer fan/blower (if the furnace is relatively recent) to create a column of air flowing up the chimney; Heat ignitor or start spark-ignition system; Open gas valve to ignite main burners; Wait (if furnace is relatively recent) until the heat exchanger is at proper operating temperature before starting main blower fan or ...
The safety benefit of reducing the power delivered to a short circuit in the load is proportional to the operating current limit. Foldback current limiting is most likely to be found in a switch-mode power supply when it is a component in a product that is independently certified to meet regional safety standards. [2]
The infinite switch itself was described in a 1975 patent of George F. Esker Jr. and Otto J. Cousins of the Harper Wyman Company. This switch would reset itself as the bi-metallic strip cooled, provided a cycle of calibrated opening and closing. It also provided an indicator light that remained on as long as the knob was not in the closed position.