They are designed as simple spans supporting equally spaced concentrated loads for a floor or roof system. These concentrated loads are considered to act at the panel points of the Joist Girders. These members have been standardized for depths from 20 to 120 inches (510 to 3,050 mm), and spans to 120 feet (37,000 mm).
The staggered truss structural system consists of story-high steel trusses placed on alternating column lines on each floor so that the long axis of one truss is always between the trusses on the floor below. [4] The system staggers trusses on a 12’ module, meaning that on any given floor the trusses were 24’ apart. [2]
Cremona diagram for a plane truss. The Cremona diagram, also known as the Cremona-Maxwell method, is a graphical method used in statics of trusses to determine the forces in members (graphic statics). The method was developed by the Italian mathematician Luigi Cremona.
In engineering, span is the distance between two adjacent structural supports (e.g., two piers) of a structural member (e.g., a beam). Span is measured in the horizontal direction either between the faces of the supports (clear span) or between the centers of the bearing surfaces (effective span): [1] A span can be closed by a solid beam or by ...
The Precast/Prestressed Concrete Institute (PCI) published the double tee load capacity calculation (load tables) for the first time in the PCI Design Handbook in 1971. The load tables use the code to identify double tee span type by using the width in feet, followed by "DT", followed by depth in inches, for example, 4DT14 is for 4-foot (1.2 m ...
These load factors are, roughly, a ratio of the theoretical design strength to the maximum load expected in service. They are developed to help achieve the desired level of reliability of a structure [ 6 ] based on probabilistic studies that take into account the load's originating cause, recurrence, distribution, and static or dynamic nature.
[5] [3] As a rule of thumb, the depth should be 1 ⁄ 24 of the span. [5] The width of the ribs is typically 130 mm (5 in) to 150 mm (6 in), and ribs usually have steel rod reinforcements. [5] The distance between ribs is typically 915 mm (3 ft). [3] The height of the ribs and beams should be 1 ⁄ 25 of the span between columns. [3]
An 1883 article from The American Architect and Building News compares three alternatives in a hypothetical railway station "in which the second story is devoted to offices, and where we must use girders to support the second floor of 25-foot span, and not less than 12 feet on centres if we can avoid it.