enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Open web steel joist - Wikipedia

    en.wikipedia.org/wiki/Open_web_steel_joist

    They are designed as simple spans supporting equally spaced concentrated loads for a floor or roof system. These concentrated loads are considered to act at the panel points of the Joist Girders. These members have been standardized for depths from 20 to 120 inches (510 to 3,050 mm), and spans to 120 feet (37,000 mm).

  3. Cremona diagram - Wikipedia

    en.wikipedia.org/wiki/Cremona_diagram

    Cremona diagram for a plane truss. The Cremona diagram, also known as the Cremona-Maxwell method, is a graphical method used in statics of trusses to determine the forces in members (graphic statics). The method was developed by the Italian mathematician Luigi Cremona.

  4. Staggered truss system - Wikipedia

    en.wikipedia.org/wiki/Staggered_truss_system

    The staggered truss structural system consists of story-high steel trusses placed on alternating column lines on each floor so that the long axis of one truss is always between the trusses on the floor below. [4] The system staggers trusses on a 12’ module, meaning that on any given floor the trusses were 24’ apart. [2]

  5. Span (engineering) - Wikipedia

    en.wikipedia.org/wiki/Span_(engineering)

    In engineering, span is the distance between two adjacent structural supports (e.g., two piers) of a structural member (e.g., a beam). Span is measured in the horizontal direction either between the faces of the supports (clear span) or between the centers of the bearing surfaces (effective span): [1] A span can be closed by a solid beam or by ...

  6. Waffle slab - Wikipedia

    en.wikipedia.org/wiki/Waffle_slab

    [5] [3] As a rule of thumb, the depth should be 1 ⁄ 24 of the span. [5] The width of the ribs is typically 130 mm (5 in) to 150 mm (6 in), and ribs usually have steel rod reinforcements. [5] The distance between ribs is typically 915 mm (3 ft). [3] The height of the ribs and beams should be 1 ⁄ 25 of the span between columns. [3]

  7. Truss - Wikipedia

    en.wikipedia.org/wiki/Truss

    The parallel chord truss, or flat truss, gets its name from its parallel top and bottom chords. It is often used for floor construction. A combination of the two is a truncated truss, used in hip roof construction. A metal plate-connected wood truss is a roof or floor truss whose wood members are connected with metal connector plates.

  8. Double tee - Wikipedia

    en.wikipedia.org/wiki/Double_tee

    The Precast/Prestressed Concrete Institute (PCI) published the double tee load capacity calculation (load tables) for the first time in the PCI Design Handbook in 1971. The load tables use the code to identify double tee span type by using the width in feet, followed by "DT", followed by depth in inches, for example, 4DT14 is for 4-foot (1.2 m ...

  9. Michell structures - Wikipedia

    en.wikipedia.org/wiki/Michell_structures

    Michell structures are structures that are optimal based on the criteria defined by A.G.M. Michell in his frequently referenced 1904 paper. [1]Michell states that “a frame (today called truss) (is optimal) attains the limit of economy of material possible in any frame-structure under the same applied forces, if the space occupied by it can be subjected to an appropriate small deformation ...