A zone valve is a specific type of valve used to control the flow of water or steam in a hydronic heating or cooling system. In the interest of improving efficiency and occupant comfort, such systems are commonly divided up into multiple zones. [ 1 ]
The boiler will also fire (regardless of thermostat state) when the boiler water temperature goes below a range around the low limit, ensuring that the boiler water temperature remains above a certain point. The low limit is intended for tankless domestic hot water; it ensures that boiler water is always warm enough to heat the domestic hot water.
The thermostat controls the fan speed and/or the flow of water or refrigerant to the heat exchanger using a control valve. Due to their simplicity, flexibility, and easy maintenance, fan coil units can be more economical to install than ducted 100% fresh air systems (VAV) or central heating systems with air handling units or chilled beams. FCUs ...
The heat from the collector can be transferred to water in two ways: directly where water circulates through the collector, or indirectly where an anti-freeze solution carries the heat from the collector and transfers it to water in the tank via a heat exchanger. Convection allows for the movement of the heated liquid out of the solar collector ...
Double pipe heat exchanger Fixed straight tubes heat exchanger: U-shaped tubes heat exchanger Spiral heat exchanger Covered gas vent Curved gas vent Air filter: Funnel or tundish: Steam trap: Viewing glass Pressure reducing valve: Valve: Gate valve: Control valve: Manual valve Check valve: Needle valve: Butterfly valve: Diaphragm valve: Ball ...
Hydronic balancing, also called hydraulic balancing, is the process of optimizing the distribution of water in a building's hydronic heating or cooling system by equalizing the system pressure. In a balanced system every radiator is set to receive the proper amount of fluid in order to provide the intended indoor climate at optimum energy ...
There are three main categories for water temperature controlling devices: Heat Source, Group Control, and Point-of-Use. Heat Source. These are used with central heating systems that use water as a medium. Tempering valves for use on hot water heat distribution systems; High flow rates suitable for use in under floor (radiant) heating applications
Pressure independent control valves are used to limit the flow to the fan coil terminal and air handling unit. This flow is not affected by changes in inlet pressure. A diaphragm within the valve keeps the outlet pressure constant, and this delivers a constant flow to the terminal. The added advantage of pressure independent control valves is ...