enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Fault current limiter - Wikipedia

    en.wikipedia.org/wiki/Fault_current_limiter

    A simple solution is to add electrical impedance to the circuit. This limits the rate at which current can increase, which limits the level the fault current can rise to before the breaker is opened. However, this also limits the ability of the circuit to satisfy rapidly changing demand, so the addition or removal of large loads causes unstable ...

  3. Current limiting - Wikipedia

    en.wikipedia.org/wiki/Current_limiting

    The safety benefit of reducing the power delivered to a short circuit in the load is proportional to the operating current limit. Foldback current limiting is most likely to be found in a switch-mode power supply when it is a component in a product that is independently certified to meet regional safety standards. [2]

  4. Contact resistance - Wikipedia

    en.wikipedia.org/wiki/Contact_resistance

    It occurs at electrical connections such as switches, connectors, breakers, contacts, and measurement probes. Contact resistance values are typically small (in the microohm to milliohm range). Contact resistance values are typically small (in the microohm to milliohm range).

  5. Circuit total limitation - Wikipedia

    en.wikipedia.org/wiki/Circuit_total_limitation

    If a panelboard with a sufficient number of breaker positions is installed in the first place, the need for non-CTL breakers should be eliminated. In their 2019 catalog Eaton now specifies that their non-CTL breakers are "Suitable for use in plug-on neutral style loadcenters" [ 4 ] which negates the replacement only rule.

  6. Current limiting reactor - Wikipedia

    en.wikipedia.org/wiki/Current_limiting_reactor

    In electrical engineering, current limiting reactors can reduce short-circuit currents, which result from plant expansions and power source additions, to levels that can be adequately handled by existing distribution equipment. [1] They can also be used in high voltage electric power transmission grids for a similar purpose.

  7. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  8. Bootleg ground - Wikipedia

    en.wikipedia.org/wiki/Bootleg_ground

    A receptacle with a bootleg ground. In building wiring installed with separate neutral and protective ground bonding conductors (a TN-S network), a bootleg ground (or a false ground) is a connection between the neutral side of a receptacle or light fixture and the ground lug or enclosure of the wiring device.

  9. Reference designator - Wikipedia

    en.wikipedia.org/wiki/Reference_designator

    Connectors on this cable would be designated: 1A1W35P1; 1A1W35P2; ASME Y14.44-2008 continues the convention of Plug P and Jack J when assigning references for electrical connectors in assemblies where a J (or jack) is the more fixed and P (or plug) is the less fixed of a connector pair, without regard to the gender of the connector contacts.