Where more current carrying capacity is required, such as between generator sets and distribution boards, VEAM Powerlocks or Cam-Loks may be used. These connectors are single pole so five are required to accommodate all three phases, neutral and ground. Powerlocks have a rating of 400 A or 660 A at 1 kV.
The most common form is the 16 series, rated at 400 amperes with 105 °C terminations. Also in common use is the 15 series (mini-cam), rated at 150 amperes. A larger version is made denoted as the 17 series with ratings up to 760 A. A ball nose version and a longer nose standard version exist—the latter is the most common.
Powerlock connectors are available in 400 A and 660 A versions. [4] All versions can be used for single-phase and, much more commonly, three-phase applications. Three phase connections require five separate cables (or four if neutral is not required).
The consequences of a two- or three-phase fault between the generator and the first circuit breaker are therefore much more serious and often result in severe damage to the busbars and nearby equipment. Isolated-phase bus is made in ratings from 3000 amperes to 45,000 amperes, and rated for voltages from 5000 volts up to about 35,000 volts.
A small metal, plastic or fiberglass junction box may form part of an electrical conduit or thermoplastic-sheathed cable (TPS) wiring system in a building. If designed for surface mounting, it is used mostly in ceilings, concrete or concealed behind an access panel—particularly in domestic or commercial buildings [2].
Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!
Discover the best free online games at AOL.com - Play board, card, casino, puzzle and many more online games while chatting with others in real-time.
Generator circuit breaker rated for 17.5 kV and 63 kA. Generator circuit breakers (GCB) are connected between a generator and the step-up voltage transformer. They are generally used at the outlet of high-power generators (30 MVA to 1800 MVA) in order to protect them in a reliable, fast and economic manner.