Duct leakage test in the US. A duct leakage tester is a diagnostic tool designed to measure the airtightness of forced air heating, ventilating and air-conditioning (HVAC) ductwork. A duct leakage tester consists of a calibrated fan for measuring an air flow rate and a pressure sensing device to measure the pressure created by the fan flow.
ANSI/AMCA Standard 230 - Laboratory Methods of Testing Air Circulating Fans for Rating and Certification establishes uniform methods of laboratory testing for air circulating fans in order to determine performance in terms of thrust for rating, certification or guarantee purposes. The 1999 version, in general, described a method to determine ...
The relationship between pressure and leakage air flow rate is defined by the power law model between the airflow rate and the pressure difference across the ductwork envelope as follows: q L =C L ∆p n. where: q L is the volumetric leakage airflow rate expressed in L.s −1; C L is the air leakage coefficient expressed in L.s −1.Pa −n
Duct leakage testing of forced air heating/cooling systems - both supply (vents) ducts and return ducts can be tested to determine if and how much they leak air. A duct test can be combined with a blower door test to measure the total leakage to outside, measuring effective leakage to the outside of the house only.
In heating, ventilation, and air conditioning (HVAC), testing, adjusting and balancing (TAB) are the three major steps used to achieve proper operation of heating, ventilation, and air conditioning systems. TAB usually refers to commercial building construction and the specialized contractors who employ personnel that perform this service.
An initial verification test must then be done within 30/120 days, and then a follow-up test within 10 days of that. There are additional clauses for extensions if needed. If the leak is not to be repaired, there must be a plan to retire or retrofit the appliance within 30 days, to be completed within one year.
Performance testing, such as a blower door test for air leakage, outside and total duct leakage, and mechanical ventilation testing is usually part of the rating. Confirmed, Sampled, and Threshold Ratings that are built above code requirements are registered with public databases such as the RESNET Registry [8] and the BSI Registry. [9]
The most common technique to measure airtightness is the fan pressurization method, also known as the blower door test. It is measured by the number of air changes per hour (ACH) that occur when there is a differential pressure of 50 pascals between outside and inside the building.