A floating ground is a reference point for electrical potential in a circuit which is galvanically isolated from actual earth ground. Most electrical circuits have a ground which is electrically connected to the Earth, hence the name "ground". The ground is said to be floating when this connection does not exist. [1]
English: Active indirect water heater. 1: Municipal water feed 2: Fluid from water storage tank to external (passive) heat source; passive heat source can be the ground (soil or groundwater), sun or air; eg via heat pump, or thermodynamic solar panel 3: Fluid from heat pump, or thermodynamic solar panel to water storage tank 4: Pump, actuator, controller and other parts 5: Water heater 6 ...
The EG circuit includes all of the metal conduit, outlet boxes, and metal enclosures that contain the wiring and must be grounded to provide a safe return path in case of fault currents. The IG provides an insulated, separate ground path for the ground reference in electronic equipment, such as computers, hospital equipment, and audio equipment.
With lamp cord wire the ribbed wire is the neutral, and the smooth wire is the hot. NEC 2008 400.22(f) allows surface marking with ridged, grooves or white stripes on the surface of lamp cord. NEC 2008 400.22(f) allows surface marking with ridged, grooves or white stripes on the surface of lamp cord.
The ground potential at different outlets may differ by as much as 10 to 20 volts [4] due to voltage drops from these currents. The diagram shows leakage current from an appliance such as an electric motor A flowing through the building's ground system G to the neutral wire at the utility ground bonding point at the service panel.
A ground connection that is missing or of inadequate capacity may not provide the protective functions as intended during a fault in the connected equipment. Extra connections between ground and circuit neutral may result in circulating current in the ground path, stray current introduced in the earth or in a structure, and stray voltage.
The ground shield of S, along with the ground wire ("third wire") P in the components' power cord and the building's utility ground wiring G form a ground loop. One of the best ways to prevent such a ground loop is to insert an isolation transformer in the signal cable S, as shown. The transformer breaks the conductive path between the ground ...