Search results
Results from the WOW.Com Content Network
Column chromatography in chemistry is a chromatography method used to isolate a single chemical compound from a mixture. Chromatography is able to separate substances based on differential absorption of compounds to the adsorbent; compounds move through the column at different rates, allowing them to be separated into fractions.
The mobile phase consists of the sample being separated/analyzed and the solvent that moves the sample through the column. In the case of HPLC the mobile phase consists of a non-polar solvent(s) such as hexane in normal phase or a polar solvent such as methanol in reverse phase chromatography and the sample being separated. The mobile phase ...
In chromatography, the retardation factor (R) is the fraction of an analyte in the mobile phase of a chromatographic system. [1] In planar chromatography in particular, the retardation factor R F is defined as the ratio of the distance traveled by the center of a spot to the distance traveled by the solvent front. [2]
Elution principle of column chromatography. In analytical and organic chemistry, elution is the process of extracting one material from another by washing with a solvent: washing of loaded ion-exchange resins to remove captured ions, or eluting proteins or other biopolymers from a gel electrophoresis or chromatography column.
The two components of the mobile phase are typically termed "A" and "B"; A is the "weak" solvent which allows the solute to elute only slowly, while B is the "strong" solvent which rapidly elutes the solutes from the column. In reversed-phase chromatography, solvent A is often water or an aqueous buffer, while B is an organic solvent miscible ...
[10]: 275ff When one of the solvents is water and the other is a non-polar solvent, then the log P value is a measure of lipophilicity or hydrophobicity. [ 10 ] : 275ff [ 11 ] : 6 The defined precedent is for the lipophilic and hydrophilic phase types to always be in the numerator and denominator respectively; for example, in a biphasic system ...
In reversed phase chromatography, the most polar compounds elute first with the more nonpolar compounds eluting later. The mobile phase is generally a mixture of water and miscible polarity-modifying organic solvent, such as methanol, acetonitrile or THF. Retention increases as the fraction of the polar solvent (water) in the mobile phase is ...
Dimethylacetamide (DMAc or DMA) is the organic compound with the formula CH 3 C(O)N(CH 3) 2. This colorless, water-miscible, high-boiling liquid is commonly used as a polar solvent in organic synthesis. DMA is miscible with most other solvents, although it is poorly soluble in aliphatic hydrocarbons.