  2. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage protection device, that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating leakage current to ground or ...

  3. National Electrical Code - Wikipedia

    en.wikipedia.org/wiki/National_Electrical_Code

    NEMA connectors implement these requirements. The NEC also permits grounding-type receptacles in non-grounded wiring protected by a GFCI; this only applies when old non-grounded receptacles are replaced with grounded receptacles, and the new receptacles must be marked with 'No equipment ground' and 'GFCI Protected' . 240 V receptacle faces

  4. Earth-leakage protection device - Wikipedia

    en.wikipedia.org/wiki/Earth-leakage_circuit_breaker

    If the wrong type was used on an installation, the level of protection given could be substantially less than that intended, in particular the voltage operated type can only protect against faults or shocks to metalwork connected to the circuit ground, connected to the VO-ELCB, it cannot detect current leaving a live wire and running to ground ...

  5. Three-prong adaptor - Wikipedia

    en.wikipedia.org/wiki/Three-prong_adaptor

    A safer and more reliable alternative identified in the US and Canadian electrical codes is to replace the outlet with a Ground Fault Circuit Interrupter (GFCI) breaker outlet. [3] Cheater plugs are also used to break ground loops in audio systems. [5] This practice has been condemned as disregarding electrical safety.

  6. Earthing system - Wikipedia

    en.wikipedia.org/wiki/Earthing_system

    System earthing serves a purpose of electrical safety throughout the system that is not caused by a short circuit or other electrical fault.It prevents static buildup and helps protect (as part of a surge protection system) against power surges caused by nearby lightning strikes or switching.

  7. Air gap (plumbing) - Wikipedia

    en.wikipedia.org/wiki/Air_gap_(plumbing)

    This "air gap" is visible above the sink as a small cylindrical fixture mounted near the faucet. In the base cabinet under the sink, the drain hose from the dishwasher feeds the "top" of the air gap, and the "bottom" of the air gap is plumbed into the sink drain below the basket, or into a garbage disposal unit. When installed and maintained ...

  8. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    The now-deprecated NEMA 10-30 has a neutral pin (at top of photo), but does not have a dedicated safety grounding pin. NEMA 10 connectors are a now deprecated type that had formerly been popular in the United States for use with high-power electric clothes dryers, kitchen ranges, and other high-power equipment. NEMA 14-30R and -50R connectors ...

  9. Arc-fault circuit interrupter - Wikipedia

    en.wikipedia.org/wiki/Arc-fault_circuit_interrupter

    (d) The circuit breaker and the OBC AFCI must be listed to meet the requirements of a system combination-type AFCI. Options 5 and 6 are the same options as we've seen in this section in the past but just included as positive text instead of being an exception. These options are required for the following areas in dwelling units: (1) Kitchens